Fix typos from temperature rework

Followup to #12201
This commit is contained in:
Scott Lahteine 2019-03-10 08:27:41 -05:00
parent 2efbcc90c5
commit 33a08fc6f7
2 changed files with 11 additions and 11 deletions

View file

@ -629,7 +629,7 @@ int Temperature::getHeaterPower(const int heater) {
SBI(fanState, pgm_read_byte(&fanBit[e]));
#if HAS_TEMP_CHAMBER
if (temp_chambercurrent > EXTRUDER_AUTO_FAN_TEMPERATURE)
if (temp_chamber.current > EXTRUDER_AUTO_FAN_TEMPERATURE)
SBI(fanState, pgm_read_byte(&fanBit[6]));
#endif
@ -1053,14 +1053,14 @@ void Temperature::manage_heater() {
if (PENDING(ms, next_chamber_check_ms)) return;
next_chamber_check_ms = ms + CHAMBER_CHECK_INTERVAL;
if (WITHIN(temp_chambercurrent, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
if (WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
if (temp_chambercurrent >= temp_chamber.target + CHAMBER_HYSTERESIS)
if (temp_chamber.current >= temp_chamber.target + CHAMBER_HYSTERESIS)
temp_chamber.soft_pwm_amount = 0;
else if (temp_chambercurrent <= temp_chamber.target - (CHAMBER_HYSTERESIS))
else if (temp_chamber.current <= temp_chamber.target - (CHAMBER_HYSTERESIS))
temp_chamber.soft_pwm_amount = MAX_CHAMBER_POWER >> 1;
#else // !PIDTEMPCHAMBER && !CHAMBER_LIMIT_SWITCHING
temp_chamber.soft_pwm_amount = temp_chambercurrent < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0;
temp_chamber.soft_pwm_amount = temp_chamber.current < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0;
#endif
}
else {
@ -1069,11 +1069,11 @@ void Temperature::manage_heater() {
}
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
thermal_runaway_protection(tr_state_machine_chamber, temp_chambercurrent, temp_chamber.target, -2, THERMAL_PROTECTION_CHAMBER_PERIOD, THERMAL_PROTECTION_CHAMBER_HYSTERESIS);
thermal_runaway_protection(tr_state_machine_chamber, temp_chamber.current, temp_chamber.target, -2, THERMAL_PROTECTION_CHAMBER_PERIOD, THERMAL_PROTECTION_CHAMBER_HYSTERESIS);
#endif
// TODO: Implement true PID pwm
//temp_bed.soft_pwm_amount = WITHIN(temp_chambercurrent, CHAMBER_MINTEMP, CHAMBER_MAXTEMP) ? (int)get_pid_output_chamber() >> 1 : 0;
//temp_bed.soft_pwm_amount = WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP) ? (int)get_pid_output_chamber() >> 1 : 0;
#endif // HAS_HEATED_CHAMBER
@ -1235,7 +1235,7 @@ void Temperature::updateTemperaturesFromRawValues() {
temp_bed.current = analog_to_celsius_bed(temp_bed.raw);
#endif
#if HAS_TEMP_CHAMBER
temp_chambercurrent = analog_to_celsius_chamber(temp_chamber.raw);
temp_chamber.current = analog_to_celsius_chamber(temp_chamber.raw);
#endif
#if ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
redundant_temperature = analog_to_celsius_hotend(redundant_temperature_raw, 1);

View file

@ -652,10 +652,10 @@ class Temperature {
#if ENABLED(SHOW_TEMP_ADC_VALUES)
FORCE_INLINE static int16_t rawChamberTemp() { return temp_chamber.raw; }
#endif
FORCE_INLINE static float degChamber() { return temp_chambercurrent; }
FORCE_INLINE static float degChamber() { return temp_chamber.current; }
#if HAS_HEATED_CHAMBER
FORCE_INLINE static bool isHeatingChamber() { return temp_chamber.target > temp_chambercurrent; }
FORCE_INLINE static bool isCoolingChamber() { return temp_chamber.target < temp_chambercurrent; }
FORCE_INLINE static bool isHeatingChamber() { return temp_chamber.target > temp_chamber.current; }
FORCE_INLINE static bool isCoolingChamber() { return temp_chamber.target < temp_chamber.current; }
FORCE_INLINE static int16_t degTargetChamber() {return temp_chamber.target; }
#endif
#endif // HAS_TEMP_CHAMBER