Clarifying M280 command in Bed Auto Leveling section.
This commit is contained in:
parent
b832f5b9f6
commit
73c82e7ad8
|
@ -274,7 +274,7 @@ In order to get the servo working, you need to enable:
|
|||
|
||||
The first define tells firmware how many servos you have.
|
||||
The second tells what axis this servo will be attached to. In the example above, we have a servo in Z axis.
|
||||
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle}
|
||||
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle} (example: M280 P0 S60 moves the servo to 60º)
|
||||
|
||||
Next you need to define the Z endstop (probe) offset from hotend.
|
||||
My preferred method:
|
||||
|
|
Loading…
Reference in a new issue