Merge pull request #6858 from thinkyhead/bf_leveling_patch
Fixes for PROBE_MANUALLY and LCD_BED_LEVELING
This commit is contained in:
commit
73ed0c63b4
1
.gitignore
vendored
1
.gitignore
vendored
|
@ -52,6 +52,7 @@ tags
|
|||
*.lo
|
||||
*.o
|
||||
*.obj
|
||||
*.ino.cpp
|
||||
|
||||
# Precompiled Headers
|
||||
*.gch
|
||||
|
|
|
@ -3800,6 +3800,10 @@ void home_all_axes() { gcode_G28(true); }
|
|||
|
||||
#if ENABLED(MESH_BED_LEVELING) || ENABLED(PROBE_MANUALLY)
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY) && ENABLED(LCD_BED_LEVELING)
|
||||
extern bool lcd_wait_for_move;
|
||||
#endif
|
||||
|
||||
inline void _manual_goto_xy(const float &x, const float &y) {
|
||||
const float old_feedrate_mm_s = feedrate_mm_s;
|
||||
|
||||
|
@ -3822,6 +3826,10 @@ void home_all_axes() { gcode_G28(true); }
|
|||
|
||||
feedrate_mm_s = old_feedrate_mm_s;
|
||||
stepper.synchronize();
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY) && ENABLED(LCD_BED_LEVELING)
|
||||
lcd_wait_for_move = false;
|
||||
#endif
|
||||
}
|
||||
|
||||
#endif
|
||||
|
@ -4190,7 +4198,7 @@ void home_all_axes() { gcode_G28(true); }
|
|||
if (!g29_in_progress) {
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY) || ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
abl_probe_index = 0;
|
||||
abl_probe_index = -1;
|
||||
#endif
|
||||
|
||||
abl_should_enable = planner.abl_enabled;
|
||||
|
@ -4397,30 +4405,40 @@ void home_all_axes() { gcode_G28(true); }
|
|||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
|
||||
const bool seenA = parser.seen('A'), seenQ = parser.seen('Q');
|
||||
|
||||
// For manual probing, get the next index to probe now.
|
||||
// On the first probe this will be incremented to 0.
|
||||
if (!seenA && !seenQ) {
|
||||
++abl_probe_index;
|
||||
g29_in_progress = true;
|
||||
}
|
||||
|
||||
// Abort current G29 procedure, go back to ABLStart
|
||||
if (parser.seen('A') && g29_in_progress) {
|
||||
if (seenA && g29_in_progress) {
|
||||
SERIAL_PROTOCOLLNPGM("Manual G29 aborted");
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
soft_endstops_enabled = enable_soft_endstops;
|
||||
#endif
|
||||
planner.abl_enabled = abl_should_enable;
|
||||
g29_in_progress = false;
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
lcd_wait_for_move = false;
|
||||
#endif
|
||||
}
|
||||
|
||||
// Query G29 status
|
||||
if (parser.seen('Q')) {
|
||||
if (!g29_in_progress)
|
||||
SERIAL_PROTOCOLLNPGM("Manual G29 idle");
|
||||
else {
|
||||
SERIAL_PROTOCOLPAIR("Manual G29 point ", abl_probe_index + 1);
|
||||
if (verbose_level || seenQ) {
|
||||
SERIAL_PROTOCOLPGM("Manual G29 ");
|
||||
if (g29_in_progress) {
|
||||
SERIAL_PROTOCOLPAIR("point ", abl_probe_index + 1);
|
||||
SERIAL_PROTOCOLLNPAIR(" of ", abl2);
|
||||
}
|
||||
else
|
||||
SERIAL_PROTOCOLLNPGM("idle");
|
||||
}
|
||||
|
||||
if (parser.seen('A') || parser.seen('Q')) return;
|
||||
|
||||
// Fall through to probe the first point
|
||||
g29_in_progress = true;
|
||||
if (seenA || seenQ) return;
|
||||
|
||||
if (abl_probe_index == 0) {
|
||||
// For the initial G29 save software endstop state
|
||||
|
@ -4458,20 +4476,20 @@ void home_all_axes() { gcode_G28(true); }
|
|||
|
||||
#if ABL_GRID
|
||||
|
||||
// Find a next point to probe
|
||||
// On the first G29 this will be the first probe point
|
||||
// Skip any unreachable points
|
||||
while (abl_probe_index < abl2) {
|
||||
|
||||
// Set xCount, yCount based on abl_probe_index, with zig-zag
|
||||
PR_OUTER_VAR = abl_probe_index / PR_INNER_END;
|
||||
PR_INNER_VAR = abl_probe_index - (PR_OUTER_VAR * PR_INNER_END);
|
||||
|
||||
bool zig = (PR_OUTER_VAR & 1) != ((PR_OUTER_END) & 1);
|
||||
// Probe in reverse order for every other row/column
|
||||
bool zig = (PR_OUTER_VAR & 1); // != ((PR_OUTER_END) & 1);
|
||||
|
||||
if (zig) PR_INNER_VAR = (PR_INNER_END - 1) - PR_INNER_VAR;
|
||||
|
||||
const float xBase = left_probe_bed_position + xGridSpacing * xCount,
|
||||
yBase = front_probe_bed_position + yGridSpacing * yCount;
|
||||
const float xBase = xCount * xGridSpacing + left_probe_bed_position,
|
||||
yBase = yCount * yGridSpacing + front_probe_bed_position;
|
||||
|
||||
xProbe = floor(xBase + (xBase < 0 ? 0 : 0.5));
|
||||
yProbe = floor(yBase + (yBase < 0 ? 0 : 0.5));
|
||||
|
@ -4488,7 +4506,6 @@ void home_all_axes() { gcode_G28(true); }
|
|||
// Is there a next point to move to?
|
||||
if (abl_probe_index < abl2) {
|
||||
_manual_goto_xy(xProbe, yProbe); // Can be used here too!
|
||||
++abl_probe_index;
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
|
@ -4497,10 +4514,9 @@ void home_all_axes() { gcode_G28(true); }
|
|||
return;
|
||||
}
|
||||
else {
|
||||
// Then leveling is done!
|
||||
// G29 finishing code goes here
|
||||
|
||||
// After recording the last point, activate abl
|
||||
// Leveling done! Fall through to G29 finishing code below
|
||||
|
||||
SERIAL_PROTOCOLLNPGM("Grid probing done.");
|
||||
g29_in_progress = false;
|
||||
|
||||
|
@ -4514,9 +4530,8 @@ void home_all_axes() { gcode_G28(true); }
|
|||
|
||||
// Probe at 3 arbitrary points
|
||||
if (abl_probe_index < 3) {
|
||||
xProbe = LOGICAL_X_POSITION(points[i].x);
|
||||
yProbe = LOGICAL_Y_POSITION(points[i].y);
|
||||
++abl_probe_index;
|
||||
xProbe = LOGICAL_X_POSITION(points[abl_probe_index].x);
|
||||
yProbe = LOGICAL_Y_POSITION(points[abl_probe_index].y);
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
|
@ -4587,7 +4602,7 @@ void home_all_axes() { gcode_G28(true); }
|
|||
yProbe = floor(yBase + (yBase < 0 ? 0 : 0.5));
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
indexIntoAB[xCount][yCount] = ++abl_probe_index;
|
||||
indexIntoAB[xCount][yCount] = ++abl_probe_index; // 0...
|
||||
#endif
|
||||
|
||||
#if IS_KINEMATIC
|
||||
|
@ -4665,7 +4680,10 @@ void home_all_axes() { gcode_G28(true); }
|
|||
// G29 Finishing Code
|
||||
//
|
||||
// Unless this is a dry run, auto bed leveling will
|
||||
// definitely be enabled after this point
|
||||
// definitely be enabled after this point.
|
||||
//
|
||||
// If code above wants to continue leveling, it should
|
||||
// return or loop before this point.
|
||||
//
|
||||
|
||||
// Restore state after probing
|
||||
|
@ -4675,6 +4693,10 @@ void home_all_axes() { gcode_G28(true); }
|
|||
if (DEBUGGING(LEVELING)) DEBUG_POS("> probing complete", current_position);
|
||||
#endif
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY) && ENABLED(LCD_BED_LEVELING)
|
||||
lcd_wait_for_move = false;
|
||||
#endif
|
||||
|
||||
// Calculate leveling, print reports, correct the position
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
|
|
|
@ -1344,9 +1344,8 @@ void MarlinSettings::reset() {
|
|||
#else
|
||||
#define LINEAR_UNIT(N) N
|
||||
#define VOLUMETRIC_UNIT(N) N
|
||||
SERIAL_ECHOLNPGM(" G21 ; Units in mm\n");
|
||||
SERIAL_ECHOLNPGM(" G21 ; Units in mm");
|
||||
#endif
|
||||
SERIAL_EOL;
|
||||
|
||||
#if ENABLED(ULTIPANEL)
|
||||
|
||||
|
@ -1361,12 +1360,13 @@ void MarlinSettings::reset() {
|
|||
serialprintPGM(parser.temp_units_name());
|
||||
#else
|
||||
#define TEMP_UNIT(N) N
|
||||
SERIAL_ECHOLNPGM(" M149 C ; Units in Celsius\n");
|
||||
SERIAL_ECHOLNPGM(" M149 C ; Units in Celsius");
|
||||
#endif
|
||||
SERIAL_EOL;
|
||||
|
||||
#endif
|
||||
|
||||
SERIAL_EOL;
|
||||
|
||||
/**
|
||||
* Volumetric extrusion M200
|
||||
*/
|
||||
|
|
887
Marlin/ultralcd.cpp
Normal file → Executable file
887
Marlin/ultralcd.cpp
Normal file → Executable file
File diff suppressed because it is too large
Load diff
Loading…
Reference in a new issue