Fix a "Heating failed" error
Addressing #3085. If the target_temperature is set directly it never invokes or disables the timer set in `start_watching_heater`, so after _stopping a print_ or turning off _all heaters_ you could get a “Heating failed” error.
This commit is contained in:
parent
7bb7ac8353
commit
81aab828e2
|
@ -1112,13 +1112,13 @@ void disable_all_heaters() {
|
||||||
setTargetBed(0);
|
setTargetBed(0);
|
||||||
|
|
||||||
#define DISABLE_HEATER(NR) { \
|
#define DISABLE_HEATER(NR) { \
|
||||||
target_temperature[NR] = 0; \
|
setTargetHotend(NR, 0); \
|
||||||
soft_pwm[NR] = 0; \
|
soft_pwm[NR] = 0; \
|
||||||
WRITE_HEATER_ ## NR (LOW); \
|
WRITE_HEATER_ ## NR (LOW); \
|
||||||
}
|
}
|
||||||
|
|
||||||
#if HAS_TEMP_0 || ENABLED(HEATER_0_USES_MAX6675)
|
#if HAS_TEMP_0 || ENABLED(HEATER_0_USES_MAX6675)
|
||||||
target_temperature[0] = 0;
|
setTargetHotend(0, 0);
|
||||||
soft_pwm[0] = 0;
|
soft_pwm[0] = 0;
|
||||||
WRITE_HEATER_0P(LOW); // Should HEATERS_PARALLEL apply here? Then change to DISABLE_HEATER(0)
|
WRITE_HEATER_0P(LOW); // Should HEATERS_PARALLEL apply here? Then change to DISABLE_HEATER(0)
|
||||||
#endif
|
#endif
|
||||||
|
|