From 84273557f9231c445ee30ee89dbcc66bc9c10e59 Mon Sep 17 00:00:00 2001 From: Stephan Date: Fri, 12 Apr 2019 22:38:10 +0200 Subject: [PATCH] Move and update heated chamber settings (#13671) Co-Authored-By: the-real-orca --- Marlin/Configuration.h | 7 +--- Marlin/Configuration_adv.h | 17 ++++++++- Marlin/src/inc/Conditionals_post.h | 2 +- Marlin/src/inc/SanityCheck.h | 2 + Marlin/src/module/temperature.cpp | 38 ++++++++++++------- Marlin/src/module/temperature.h | 20 +++------- buildroot/share/tests/megaatmega2560-tests | 2 +- config/default/Configuration.h | 7 +--- config/default/Configuration_adv.h | 17 ++++++++- .../examples/3DFabXYZ/Migbot/Configuration.h | 7 +--- .../3DFabXYZ/Migbot/Configuration_adv.h | 17 ++++++++- .../AlephObjects/TAZ4/Configuration.h | 7 +--- .../AlephObjects/TAZ4/Configuration_adv.h | 17 ++++++++- .../AliExpress/CL-260/Configuration.h | 7 +--- .../AliExpress/UM2pExt/Configuration.h | 7 +--- .../AliExpress/UM2pExt/Configuration_adv.h | 17 ++++++++- config/examples/Anet/A2/Configuration.h | 7 +--- config/examples/Anet/A2/Configuration_adv.h | 17 ++++++++- config/examples/Anet/A2plus/Configuration.h | 7 +--- .../examples/Anet/A2plus/Configuration_adv.h | 17 ++++++++- config/examples/Anet/A6/Configuration.h | 7 +--- config/examples/Anet/A6/Configuration_adv.h | 17 ++++++++- config/examples/Anet/A8/Configuration.h | 7 +--- config/examples/Anet/A8/Configuration_adv.h | 17 ++++++++- config/examples/AnyCubic/i3/Configuration.h | 7 +--- .../examples/AnyCubic/i3/Configuration_adv.h | 17 ++++++++- config/examples/ArmEd/Configuration.h | 7 +--- config/examples/ArmEd/Configuration_adv.h | 17 ++++++++- config/examples/Azteeg/X5GT/Configuration.h | 7 +--- .../BIBO/TouchX/cyclops/Configuration.h | 7 +--- .../BIBO/TouchX/cyclops/Configuration_adv.h | 17 ++++++++- .../BIBO/TouchX/default/Configuration.h | 7 +--- .../BIBO/TouchX/default/Configuration_adv.h | 17 ++++++++- config/examples/BQ/Hephestos/Configuration.h | 7 +--- .../examples/BQ/Hephestos/Configuration_adv.h | 17 ++++++++- .../examples/BQ/Hephestos_2/Configuration.h | 7 +--- .../BQ/Hephestos_2/Configuration_adv.h | 17 ++++++++- config/examples/BQ/WITBOX/Configuration.h | 7 +--- config/examples/BQ/WITBOX/Configuration_adv.h | 17 ++++++++- config/examples/Cartesio/Configuration.h | 7 +--- config/examples/Cartesio/Configuration_adv.h | 17 ++++++++- .../examples/Creality/CR-10/Configuration.h | 7 +--- .../Creality/CR-10/Configuration_adv.h | 17 ++++++++- .../examples/Creality/CR-10S/Configuration.h | 7 +--- .../Creality/CR-10S/Configuration_adv.h | 17 ++++++++- .../Creality/CR-10_5S/Configuration.h | 7 +--- .../Creality/CR-10_5S/Configuration_adv.h | 17 ++++++++- .../Creality/CR-10mini/Configuration.h | 7 +--- .../Creality/CR-10mini/Configuration_adv.h | 17 ++++++++- config/examples/Creality/CR-8/Configuration.h | 7 +--- .../Creality/CR-8/Configuration_adv.h | 17 ++++++++- .../examples/Creality/Ender-2/Configuration.h | 7 +--- .../Creality/Ender-2/Configuration_adv.h | 17 ++++++++- .../examples/Creality/Ender-3/Configuration.h | 7 +--- .../Creality/Ender-3/Configuration_adv.h | 17 ++++++++- .../examples/Creality/Ender-4/Configuration.h | 7 +--- .../Creality/Ender-4/Configuration_adv.h | 17 ++++++++- config/examples/Einstart-S/Configuration.h | 7 +--- .../examples/Einstart-S/Configuration_adv.h | 17 ++++++++- config/examples/Felix/Configuration.h | 7 +--- config/examples/Felix/Configuration_adv.h | 17 ++++++++- config/examples/Felix/DUAL/Configuration.h | 7 +--- .../FlashForge/CreatorPro/Configuration.h | 7 +--- .../FlashForge/CreatorPro/Configuration_adv.h | 17 ++++++++- .../FolgerTech/i3-2020/Configuration.h | 7 +--- .../FolgerTech/i3-2020/Configuration_adv.h | 17 ++++++++- .../examples/Formbot/Raptor/Configuration.h | 7 +--- .../Formbot/Raptor/Configuration_adv.h | 17 ++++++++- .../examples/Formbot/T_Rex_2+/Configuration.h | 7 +--- .../Formbot/T_Rex_2+/Configuration_adv.h | 17 ++++++++- .../examples/Formbot/T_Rex_3/Configuration.h | 7 +--- .../Formbot/T_Rex_3/Configuration_adv.h | 17 ++++++++- config/examples/Geeetech/A10M/Configuration.h | 7 +--- .../Geeetech/A10M/Configuration_adv.h | 17 ++++++++- config/examples/Geeetech/A20M/Configuration.h | 7 +--- .../Geeetech/A20M/Configuration_adv.h | 17 ++++++++- .../examples/Geeetech/GT2560/Configuration.h | 7 +--- .../Geeetech/I3_Pro_X-GT2560/Configuration.h | 7 +--- .../Geeetech/MeCreator2/Configuration.h | 7 +--- .../Geeetech/MeCreator2/Configuration_adv.h | 17 ++++++++- .../Prusa i3 Pro B/bltouch/Configuration.h | 7 +--- .../Prusa i3 Pro B/noprobe/Configuration.h | 7 +--- .../Geeetech/Prusa i3 Pro C/Configuration.h | 7 +--- .../Prusa i3 Pro C/Configuration_adv.h | 17 ++++++++- .../Geeetech/Prusa i3 Pro W/Configuration.h | 7 +--- .../Prusa i3 Pro W/Configuration_adv.h | 17 ++++++++- .../examples/Infitary/i3-M508/Configuration.h | 7 +--- .../Infitary/i3-M508/Configuration_adv.h | 17 ++++++++- config/examples/JGAurora/A5/Configuration.h | 7 +--- .../examples/JGAurora/A5/Configuration_adv.h | 17 ++++++++- config/examples/MakerParts/Configuration.h | 7 +--- .../examples/MakerParts/Configuration_adv.h | 17 ++++++++- config/examples/Malyan/M150/Configuration.h | 7 +--- .../examples/Malyan/M150/Configuration_adv.h | 17 ++++++++- config/examples/Malyan/M200/Configuration.h | 7 +--- .../examples/Malyan/M200/Configuration_adv.h | 17 ++++++++- .../Micromake/C1/basic/Configuration.h | 7 +--- .../Micromake/C1/enhanced/Configuration.h | 7 +--- .../Micromake/C1/enhanced/Configuration_adv.h | 17 ++++++++- config/examples/Mks/Robin/Configuration.h | 7 +--- config/examples/Mks/Robin/Configuration_adv.h | 17 ++++++++- config/examples/Mks/Sbase/Configuration.h | 7 +--- config/examples/Mks/Sbase/Configuration_adv.h | 17 ++++++++- .../Printrbot/PrintrboardG2/Configuration.h | 7 +--- .../examples/RapideLite/RL200/Configuration.h | 7 +--- .../RapideLite/RL200/Configuration_adv.h | 17 ++++++++- .../examples/RepRapPro/Huxley/Configuration.h | 7 +--- .../RepRapWorld/Megatronics/Configuration.h | 7 +--- config/examples/RigidBot/Configuration.h | 7 +--- config/examples/RigidBot/Configuration_adv.h | 17 ++++++++- config/examples/SCARA/Configuration.h | 7 +--- config/examples/SCARA/Configuration_adv.h | 17 ++++++++- .../STM32/Black_STM32F407VET6/Configuration.h | 7 +--- .../Black_STM32F407VET6/Configuration_adv.h | 17 ++++++++- .../examples/STM32/STM32F10/Configuration.h | 7 +--- config/examples/STM32/STM32F4/Configuration.h | 7 +--- .../STM32/stm32f103ret6/Configuration.h | 7 +--- config/examples/Sanguinololu/Configuration.h | 7 +--- .../examples/Sanguinololu/Configuration_adv.h | 17 ++++++++- config/examples/TheBorg/Configuration.h | 7 +--- config/examples/TheBorg/Configuration_adv.h | 17 ++++++++- config/examples/TinyBoy2/Configuration.h | 7 +--- config/examples/TinyBoy2/Configuration_adv.h | 17 ++++++++- config/examples/Tronxy/X1/Configuration.h | 7 +--- config/examples/Tronxy/X3A/Configuration.h | 7 +--- .../examples/Tronxy/X3A/Configuration_adv.h | 17 ++++++++- config/examples/Tronxy/X5S-2E/Configuration.h | 7 +--- .../Tronxy/X5S-2E/Configuration_adv.h | 17 ++++++++- config/examples/Tronxy/X5S/Configuration.h | 7 +--- config/examples/Tronxy/XY100/Configuration.h | 7 +--- .../UltiMachine/Archim1/Configuration.h | 7 +--- .../UltiMachine/Archim1/Configuration_adv.h | 17 ++++++++- .../UltiMachine/Archim2/Configuration.h | 7 +--- .../UltiMachine/Archim2/Configuration_adv.h | 17 ++++++++- config/examples/VORONDesign/Configuration.h | 7 +--- .../examples/VORONDesign/Configuration_adv.h | 17 ++++++++- .../examples/Velleman/K8200/Configuration.h | 7 +--- .../Velleman/K8200/Configuration_adv.h | 17 ++++++++- .../examples/Velleman/K8400/Configuration.h | 7 +--- .../Velleman/K8400/Configuration_adv.h | 17 ++++++++- .../Velleman/K8400/Dual-head/Configuration.h | 7 +--- .../examples/WASP/PowerWASP/Configuration.h | 7 +--- .../WASP/PowerWASP/Configuration_adv.h | 17 ++++++++- .../Wanhao/Duplicator 6/Configuration.h | 7 +--- .../Wanhao/Duplicator 6/Configuration_adv.h | 17 ++++++++- .../examples/adafruit/ST7565/Configuration.h | 7 +--- .../delta/Anycubic/Kossel/Configuration.h | 7 +--- .../delta/Anycubic/Kossel/Configuration_adv.h | 17 ++++++++- .../FLSUN/auto_calibrate/Configuration.h | 7 +--- .../FLSUN/auto_calibrate/Configuration_adv.h | 17 ++++++++- .../delta/FLSUN/kossel/Configuration.h | 7 +--- .../delta/FLSUN/kossel/Configuration_adv.h | 17 ++++++++- .../delta/FLSUN/kossel_mini/Configuration.h | 7 +--- .../FLSUN/kossel_mini/Configuration_adv.h | 17 ++++++++- .../Geeetech/Rostock 301/Configuration.h | 7 +--- .../Geeetech/Rostock 301/Configuration_adv.h | 17 ++++++++- .../delta/Hatchbox_Alpha/Configuration.h | 7 +--- .../examples/delta/MKS/SBASE/Configuration.h | 7 +--- .../delta/MKS/SBASE/Configuration_adv.h | 17 ++++++++- .../delta/Tevo Little Monster/Configuration.h | 7 +--- .../Tevo Little Monster/Configuration_adv.h | 17 ++++++++- config/examples/delta/generic/Configuration.h | 7 +--- .../delta/generic/Configuration_adv.h | 17 ++++++++- .../delta/kossel_mini/Configuration.h | 7 +--- .../delta/kossel_mini/Configuration_adv.h | 17 ++++++++- .../examples/delta/kossel_pro/Configuration.h | 7 +--- .../examples/delta/kossel_xl/Configuration.h | 7 +--- .../delta/kossel_xl/Configuration_adv.h | 17 ++++++++- .../examples/gCreate/gMax1.5+/Configuration.h | 7 +--- .../gCreate/gMax1.5+/Configuration_adv.h | 17 ++++++++- config/examples/makibox/Configuration.h | 7 +--- config/examples/makibox/Configuration_adv.h | 17 ++++++++- config/examples/tvrrug/Round2/Configuration.h | 7 +--- .../tvrrug/Round2/Configuration_adv.h | 17 ++++++++- config/examples/wt150/Configuration.h | 7 +--- config/examples/wt150/Configuration_adv.h | 17 ++++++++- 176 files changed, 1255 insertions(+), 756 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index eb3a22fc31..5faed3c8b9 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/Marlin/Configuration_adv.h b/Marlin/Configuration_adv.h index 3763ec1724..e36bfa895e 100644 --- a/Marlin/Configuration_adv.h +++ b/Marlin/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/Marlin/src/inc/Conditionals_post.h b/Marlin/src/inc/Conditionals_post.h index b1e53c608a..a4789f7d97 100644 --- a/Marlin/src/inc/Conditionals_post.h +++ b/Marlin/src/inc/Conditionals_post.h @@ -918,7 +918,7 @@ #define HAS_TEMP_HOTEND (HAS_TEMP_ADC_0 || ENABLED(HEATER_0_USES_MAX6675)) #define HAS_TEMP_BED HAS_TEMP_ADC_BED #define HAS_TEMP_CHAMBER HAS_TEMP_ADC_CHAMBER -#define HAS_HEATED_CHAMBER (HAS_TEMP_CHAMBER && PIN_EXISTS(CHAMBER_HEATER)) +#define HAS_HEATED_CHAMBER (HAS_TEMP_CHAMBER && PIN_EXISTS(HEATER_CHAMBER)) // Heaters #define HAS_HEATER_0 (PIN_EXISTS(HEATER_0)) diff --git a/Marlin/src/inc/SanityCheck.h b/Marlin/src/inc/SanityCheck.h index a927900557..d76c28bbf2 100644 --- a/Marlin/src/inc/SanityCheck.h +++ b/Marlin/src/inc/SanityCheck.h @@ -343,6 +343,8 @@ #error "MAX6675_SS2 is now MAX6675_SS2_PIN. Please update your configuration and/or pins." #elif defined(SPINDLE_LASER_ENABLE_PIN) #error "SPINDLE_LASER_ENABLE_PIN is now SPINDLE_LASER_ENA_PIN. Please update your configuration and/or pins." +#elif defined(CHAMBER_HEATER_PIN) + #error "CHAMBER_HEATER_PIN is now HEATER_CHAMBER_PIN. Please update your configuration and/or pins." #elif defined(TMC_Z_CALIBRATION) #error "TMC_Z_CALIBRATION has been deprecated in favor of Z_STEPPER_AUTO_ALIGN. Please update your configuration." #elif defined(Z_MIN_PROBE_ENDSTOP) diff --git a/Marlin/src/module/temperature.cpp b/Marlin/src/module/temperature.cpp index d8bf25747e..8f3361944d 100644 --- a/Marlin/src/module/temperature.cpp +++ b/Marlin/src/module/temperature.cpp @@ -595,10 +595,23 @@ temp_range_t Temperature::temp_range[HOTENDS] = ARRAY_BY_HOTENDS(sensor_heater_0 Temperature::Temperature() { } -int Temperature::getHeaterPower(const int heater) { +int16_t Temperature::getHeaterPower(const int8_t heater) { return ( + #if HAS_HEATED_CHAMBER + #if HAS_HEATED_BED + heater == -2 + #else + heater < 0 + #endif + ? temp_chamber.soft_pwm_amount : + #endif #if HAS_HEATED_BED - heater < 0 ? temp_bed.soft_pwm_amount : + #if HAS_HEATED_CHAMBER + heater == -1 + #else + heater < 0 + #endif + ? temp_bed.soft_pwm_amount : #endif temp_hotend[heater].soft_pwm_amount ); @@ -1073,11 +1086,11 @@ void Temperature::manage_heater() { if (WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) { #if ENABLED(CHAMBER_LIMIT_SWITCHING) - if (temp_chamber.current >= temp_chamber.target + CHAMBER_HYSTERESIS) + if (temp_chamber.current >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS) temp_chamber.soft_pwm_amount = 0; - else if (temp_chamber.current <= temp_chamber.target - (CHAMBER_HYSTERESIS)) + else if (temp_chamber.current <= temp_chamber.target - (TEMP_CHAMBER_HYSTERESIS)) temp_chamber.soft_pwm_amount = MAX_CHAMBER_POWER >> 1; - #else // !PIDTEMPCHAMBER && !CHAMBER_LIMIT_SWITCHING + #else temp_chamber.soft_pwm_amount = temp_chamber.current < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0; #endif } @@ -2017,11 +2030,7 @@ void Temperature::readings_ready() { #else #define CHAMBERCMP(A,B) ((A)>=(B)) #endif - const bool chamber_on = (temp_chamber.target > 0) - #if ENABLED(PIDTEMPCHAMBER) - || (temp_chamber.soft_pwm_amount > 0) - #endif - ; + const bool chamber_on = (temp_chamber.target > 0); if (CHAMBERCMP(temp_chamber.raw, maxtemp_raw_CHAMBER)) max_temp_error(-2); if (chamber_on && CHAMBERCMP(mintemp_raw_CHAMBER, temp_chamber.raw)) min_temp_error(-2); #endif @@ -2602,11 +2611,12 @@ void Temperature::isr() { , e ); #endif - SERIAL_ECHOPGM(" @:"); - SERIAL_ECHO(getHeaterPower(target_extruder)); + SERIAL_ECHOPAIR(" @:", getHeaterPower(target_extruder)); #if HAS_HEATED_BED - SERIAL_ECHOPGM(" B@:"); - SERIAL_ECHO(getHeaterPower(-1)); + SERIAL_ECHOPAIR(" B@:", getHeaterPower(-1)); + #endif + #if HAS_HEATED_CHAMBER + SERIAL_ECHOPAIR(" C@:", getHeaterPower(-2)); #endif #if HOTENDS > 1 HOTEND_LOOP() { diff --git a/Marlin/src/module/temperature.h b/Marlin/src/module/temperature.h index a8cfad34b3..b24f84fb58 100644 --- a/Marlin/src/module/temperature.h +++ b/Marlin/src/module/temperature.h @@ -206,16 +206,10 @@ struct PIDHeaterInfo : public HeaterInfo { typedef heater_info_t bed_info_t; #endif #endif -#if HAS_TEMP_CHAMBER - #if HAS_HEATED_CHAMBER - #if ENABLED(PIDTEMPCHAMBER) - typedef struct PIDHeaterInfo chamber_info_t; - #else - typedef heater_info_t chamber_info_t; - #endif - #else - typedef temp_info_t chamber_info_t; - #endif +#if HAS_HEATED_CHAMBER + typedef heater_info_t chamber_info_t; +#elif HAS_TEMP_CHAMBER + typedef temp_info_t chamber_info_t; #endif // Heater idle handling @@ -339,9 +333,7 @@ class Temperature { #if WATCH_CHAMBER static heater_watch_t watch_chamber; #endif - #if DISABLED(PIDTEMPCHAMBER) - static millis_t next_chamber_check_ms; - #endif + static millis_t next_chamber_check_ms; #ifdef CHAMBER_MINTEMP static int16_t mintemp_raw_CHAMBER; #endif @@ -653,7 +645,7 @@ class Temperature { /** * The software PWM power for a heater */ - static int getHeaterPower(const int heater); + static int16_t getHeaterPower(const int8_t heater); /** * Switch off all heaters, set all target temperatures to 0 diff --git a/buildroot/share/tests/megaatmega2560-tests b/buildroot/share/tests/megaatmega2560-tests index e207f3cd74..0ca2c419b7 100755 --- a/buildroot/share/tests/megaatmega2560-tests +++ b/buildroot/share/tests/megaatmega2560-tests @@ -42,7 +42,7 @@ opt_enable PIDTEMPBED FIX_MOUNTED_PROBE Z_SAFE_HOMING EEPROM_SETTINGS \ MAX7219_DEBUG LED_CONTROL_MENU CASE_LIGHT_ENABLE CASE_LIGHT_USE_NEOPIXEL CODEPENDENT_XY_HOMING BACKLASH_COMPENSATION BACKLASH_GCODE opt_enable SLOW_PWM_HEATERS THERMAL_PROTECTION_CHAMBER opt_set TEMP_SENSOR_CHAMBER 3 -opt_set CHAMBER_HEATER_PIN 45 +opt_set HEATER_CHAMBER_PIN 45 exec_test $1 $2 "RAMPS with 2 extruders, RRDFGSC, Linear ABL, LEDs, and many options" # diff --git a/config/default/Configuration.h b/config/default/Configuration.h index eb3a22fc31..5faed3c8b9 100644 --- a/config/default/Configuration.h +++ b/config/default/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/default/Configuration_adv.h b/config/default/Configuration_adv.h index 42f7dc3f58..46c2554eb6 100644 --- a/config/default/Configuration_adv.h +++ b/config/default/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/3DFabXYZ/Migbot/Configuration.h b/config/examples/3DFabXYZ/Migbot/Configuration.h index 93cefc58a7..143622824d 100644 --- a/config/examples/3DFabXYZ/Migbot/Configuration.h +++ b/config/examples/3DFabXYZ/Migbot/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/3DFabXYZ/Migbot/Configuration_adv.h b/config/examples/3DFabXYZ/Migbot/Configuration_adv.h index 994643c591..ba21fd3d20 100644 --- a/config/examples/3DFabXYZ/Migbot/Configuration_adv.h +++ b/config/examples/3DFabXYZ/Migbot/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/AlephObjects/TAZ4/Configuration.h b/config/examples/AlephObjects/TAZ4/Configuration.h index 1fd4ad8536..0720c14f0b 100644 --- a/config/examples/AlephObjects/TAZ4/Configuration.h +++ b/config/examples/AlephObjects/TAZ4/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 7 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -485,7 +480,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/AlephObjects/TAZ4/Configuration_adv.h b/config/examples/AlephObjects/TAZ4/Configuration_adv.h index 740db482ea..eebde4ff3d 100644 --- a/config/examples/AlephObjects/TAZ4/Configuration_adv.h +++ b/config/examples/AlephObjects/TAZ4/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/AliExpress/CL-260/Configuration.h b/config/examples/AliExpress/CL-260/Configuration.h index f9e6beeb5d..916bb06854 100644 --- a/config/examples/AliExpress/CL-260/Configuration.h +++ b/config/examples/AliExpress/CL-260/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/AliExpress/UM2pExt/Configuration.h b/config/examples/AliExpress/UM2pExt/Configuration.h index dbeb0f0da5..e904da3019 100644 --- a/config/examples/AliExpress/UM2pExt/Configuration.h +++ b/config/examples/AliExpress/UM2pExt/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 20 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 130 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -487,7 +482,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/AliExpress/UM2pExt/Configuration_adv.h b/config/examples/AliExpress/UM2pExt/Configuration_adv.h index c4e72a91aa..df3b97b2d8 100644 --- a/config/examples/AliExpress/UM2pExt/Configuration_adv.h +++ b/config/examples/AliExpress/UM2pExt/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Anet/A2/Configuration.h b/config/examples/Anet/A2/Configuration.h index 7c395945ac..669dee2af0 100644 --- a/config/examples/Anet/A2/Configuration.h +++ b/config/examples/Anet/A2/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Anet/A2/Configuration_adv.h b/config/examples/Anet/A2/Configuration_adv.h index f0bd8e9795..95c43b74ae 100644 --- a/config/examples/Anet/A2/Configuration_adv.h +++ b/config/examples/Anet/A2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Anet/A2plus/Configuration.h b/config/examples/Anet/A2plus/Configuration.h index 06d8906b2a..325939564e 100644 --- a/config/examples/Anet/A2plus/Configuration.h +++ b/config/examples/Anet/A2plus/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Anet/A2plus/Configuration_adv.h b/config/examples/Anet/A2plus/Configuration_adv.h index f0bd8e9795..95c43b74ae 100644 --- a/config/examples/Anet/A2plus/Configuration_adv.h +++ b/config/examples/Anet/A2plus/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Anet/A6/Configuration.h b/config/examples/Anet/A6/Configuration.h index f1a8036da4..64431b72f4 100644 --- a/config/examples/Anet/A6/Configuration.h +++ b/config/examples/Anet/A6/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 11 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 130 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -487,7 +482,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Anet/A6/Configuration_adv.h b/config/examples/Anet/A6/Configuration_adv.h index 0163ffff56..c329a3600a 100644 --- a/config/examples/Anet/A6/Configuration_adv.h +++ b/config/examples/Anet/A6/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Anet/A8/Configuration.h b/config/examples/Anet/A8/Configuration.h index db3c843483..e60533d09d 100644 --- a/config/examples/Anet/A8/Configuration.h +++ b/config/examples/Anet/A8/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 130 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -483,7 +478,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Anet/A8/Configuration_adv.h b/config/examples/Anet/A8/Configuration_adv.h index 52c16e8942..da07576626 100644 --- a/config/examples/Anet/A8/Configuration_adv.h +++ b/config/examples/Anet/A8/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/AnyCubic/i3/Configuration.h b/config/examples/AnyCubic/i3/Configuration.h index d4ae37aa46..3da19a382f 100644 --- a/config/examples/AnyCubic/i3/Configuration.h +++ b/config/examples/AnyCubic/i3/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/AnyCubic/i3/Configuration_adv.h b/config/examples/AnyCubic/i3/Configuration_adv.h index 51f84d4f87..675ddd5d46 100644 --- a/config/examples/AnyCubic/i3/Configuration_adv.h +++ b/config/examples/AnyCubic/i3/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/ArmEd/Configuration.h b/config/examples/ArmEd/Configuration.h index 8693153728..d658278ec3 100644 --- a/config/examples/ArmEd/Configuration.h +++ b/config/examples/ArmEd/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 13 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/ArmEd/Configuration_adv.h b/config/examples/ArmEd/Configuration_adv.h index 5c678649b0..7f73a21bce 100644 --- a/config/examples/ArmEd/Configuration_adv.h +++ b/config/examples/ArmEd/Configuration_adv.h @@ -54,6 +54,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -131,8 +144,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Azteeg/X5GT/Configuration.h b/config/examples/Azteeg/X5GT/Configuration.h index 52326ddcff..e8ce57851e 100644 --- a/config/examples/Azteeg/X5GT/Configuration.h +++ b/config/examples/Azteeg/X5GT/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BIBO/TouchX/cyclops/Configuration.h b/config/examples/BIBO/TouchX/cyclops/Configuration.h index 6e33f71092..1c0112e329 100644 --- a/config/examples/BIBO/TouchX/cyclops/Configuration.h +++ b/config/examples/BIBO/TouchX/cyclops/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h b/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h index 67c84bebf9..96262317b7 100644 --- a/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h +++ b/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/BIBO/TouchX/default/Configuration.h b/config/examples/BIBO/TouchX/default/Configuration.h index 193d5e8b92..ba9b968114 100644 --- a/config/examples/BIBO/TouchX/default/Configuration.h +++ b/config/examples/BIBO/TouchX/default/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 60 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BIBO/TouchX/default/Configuration_adv.h b/config/examples/BIBO/TouchX/default/Configuration_adv.h index 7cd8a52b48..f6b4ae290b 100644 --- a/config/examples/BIBO/TouchX/default/Configuration_adv.h +++ b/config/examples/BIBO/TouchX/default/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/BQ/Hephestos/Configuration.h b/config/examples/BQ/Hephestos/Configuration.h index bbbfa36a8f..efe46bd7f9 100644 --- a/config/examples/BQ/Hephestos/Configuration.h +++ b/config/examples/BQ/Hephestos/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -464,7 +459,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BQ/Hephestos/Configuration_adv.h b/config/examples/BQ/Hephestos/Configuration_adv.h index 01bb63e2b8..8dc95c14ac 100644 --- a/config/examples/BQ/Hephestos/Configuration_adv.h +++ b/config/examples/BQ/Hephestos/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/BQ/Hephestos_2/Configuration.h b/config/examples/BQ/Hephestos_2/Configuration.h index b6ea2e22de..97b8dba743 100644 --- a/config/examples/BQ/Hephestos_2/Configuration.h +++ b/config/examples/BQ/Hephestos_2/Configuration.h @@ -399,7 +399,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -418,8 +417,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -429,7 +426,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -441,7 +437,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 100 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BQ/Hephestos_2/Configuration_adv.h b/config/examples/BQ/Hephestos_2/Configuration_adv.h index e37097f3cc..3502efcc17 100644 --- a/config/examples/BQ/Hephestos_2/Configuration_adv.h +++ b/config/examples/BQ/Hephestos_2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/BQ/WITBOX/Configuration.h b/config/examples/BQ/WITBOX/Configuration.h index 5f1429be14..3002eebcec 100644 --- a/config/examples/BQ/WITBOX/Configuration.h +++ b/config/examples/BQ/WITBOX/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -464,7 +459,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/BQ/WITBOX/Configuration_adv.h b/config/examples/BQ/WITBOX/Configuration_adv.h index 01bb63e2b8..8dc95c14ac 100644 --- a/config/examples/BQ/WITBOX/Configuration_adv.h +++ b/config/examples/BQ/WITBOX/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Cartesio/Configuration.h b/config/examples/Cartesio/Configuration.h index 6c95487afd..eba8f376d7 100644 --- a/config/examples/Cartesio/Configuration.h +++ b/config/examples/Cartesio/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 415 #define HEATER_5_MAXTEMP 415 #define BED_MAXTEMP 165 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Cartesio/Configuration_adv.h b/config/examples/Cartesio/Configuration_adv.h index 461fc07c1c..86207af419 100644 --- a/config/examples/Cartesio/Configuration_adv.h +++ b/config/examples/Cartesio/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/CR-10/Configuration.h b/config/examples/Creality/CR-10/Configuration.h index 1b8e8c630a..09130f330d 100644 --- a/config/examples/Creality/CR-10/Configuration.h +++ b/config/examples/Creality/CR-10/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/CR-10/Configuration_adv.h b/config/examples/Creality/CR-10/Configuration_adv.h index bab024defc..235b59ef74 100644 --- a/config/examples/Creality/CR-10/Configuration_adv.h +++ b/config/examples/Creality/CR-10/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/CR-10S/Configuration.h b/config/examples/Creality/CR-10S/Configuration.h index b545a1ac68..8efdab2609 100644 --- a/config/examples/Creality/CR-10S/Configuration.h +++ b/config/examples/Creality/CR-10S/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/CR-10S/Configuration_adv.h b/config/examples/Creality/CR-10S/Configuration_adv.h index e95ed27b5b..4a52d57caf 100644 --- a/config/examples/Creality/CR-10S/Configuration_adv.h +++ b/config/examples/Creality/CR-10S/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/CR-10_5S/Configuration.h b/config/examples/Creality/CR-10_5S/Configuration.h index 3625b66d9a..eecd2a0ca7 100644 --- a/config/examples/Creality/CR-10_5S/Configuration.h +++ b/config/examples/Creality/CR-10_5S/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/CR-10_5S/Configuration_adv.h b/config/examples/Creality/CR-10_5S/Configuration_adv.h index 6110475398..3103766377 100644 --- a/config/examples/Creality/CR-10_5S/Configuration_adv.h +++ b/config/examples/Creality/CR-10_5S/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/CR-10mini/Configuration.h b/config/examples/Creality/CR-10mini/Configuration.h index 7f80fe3746..df9c556bce 100644 --- a/config/examples/Creality/CR-10mini/Configuration.h +++ b/config/examples/Creality/CR-10mini/Configuration.h @@ -400,7 +400,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -419,8 +418,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -430,7 +427,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -442,7 +438,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -490,7 +485,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/CR-10mini/Configuration_adv.h b/config/examples/Creality/CR-10mini/Configuration_adv.h index e2b91c1254..2f1e01aeaa 100644 --- a/config/examples/Creality/CR-10mini/Configuration_adv.h +++ b/config/examples/Creality/CR-10mini/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/CR-8/Configuration.h b/config/examples/Creality/CR-8/Configuration.h index 1324c7767a..3893c0fb9f 100644 --- a/config/examples/Creality/CR-8/Configuration.h +++ b/config/examples/Creality/CR-8/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/CR-8/Configuration_adv.h b/config/examples/Creality/CR-8/Configuration_adv.h index 0cdbd719b0..01fb18ad93 100644 --- a/config/examples/Creality/CR-8/Configuration_adv.h +++ b/config/examples/Creality/CR-8/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/Ender-2/Configuration.h b/config/examples/Creality/Ender-2/Configuration.h index 016a666fad..f693b831a5 100644 --- a/config/examples/Creality/Ender-2/Configuration.h +++ b/config/examples/Creality/Ender-2/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 75 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/Ender-2/Configuration_adv.h b/config/examples/Creality/Ender-2/Configuration_adv.h index 6d9ed0020b..6d4555b67c 100644 --- a/config/examples/Creality/Ender-2/Configuration_adv.h +++ b/config/examples/Creality/Ender-2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/Ender-3/Configuration.h b/config/examples/Creality/Ender-3/Configuration.h index 0b7f371872..201eb25105 100644 --- a/config/examples/Creality/Ender-3/Configuration.h +++ b/config/examples/Creality/Ender-3/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 125 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/Ender-3/Configuration_adv.h b/config/examples/Creality/Ender-3/Configuration_adv.h index b6d54b935b..7d5da09c9b 100644 --- a/config/examples/Creality/Ender-3/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Creality/Ender-4/Configuration.h b/config/examples/Creality/Ender-4/Configuration.h index c6dd831476..669203ec4b 100644 --- a/config/examples/Creality/Ender-4/Configuration.h +++ b/config/examples/Creality/Ender-4/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Creality/Ender-4/Configuration_adv.h b/config/examples/Creality/Ender-4/Configuration_adv.h index 7f223f69d6..a7f9a1c6b4 100644 --- a/config/examples/Creality/Ender-4/Configuration_adv.h +++ b/config/examples/Creality/Ender-4/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Einstart-S/Configuration.h b/config/examples/Einstart-S/Configuration.h index 583cc7f6db..691b1851a1 100644 --- a/config/examples/Einstart-S/Configuration.h +++ b/config/examples/Einstart-S/Configuration.h @@ -393,7 +393,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -412,8 +411,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -423,7 +420,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -435,7 +431,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -484,7 +479,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Einstart-S/Configuration_adv.h b/config/examples/Einstart-S/Configuration_adv.h index c67f930f46..9e01b476ad 100644 --- a/config/examples/Einstart-S/Configuration_adv.h +++ b/config/examples/Einstart-S/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Felix/Configuration.h b/config/examples/Felix/Configuration.h index e14b9d4dda..b2c5a2ede2 100644 --- a/config/examples/Felix/Configuration.h +++ b/config/examples/Felix/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -464,7 +459,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Felix/Configuration_adv.h b/config/examples/Felix/Configuration_adv.h index 26ac45fe55..638aef0b4c 100644 --- a/config/examples/Felix/Configuration_adv.h +++ b/config/examples/Felix/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Felix/DUAL/Configuration.h b/config/examples/Felix/DUAL/Configuration.h index ffc8b3c079..4c1d96138b 100644 --- a/config/examples/Felix/DUAL/Configuration.h +++ b/config/examples/Felix/DUAL/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -464,7 +459,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/FlashForge/CreatorPro/Configuration.h b/config/examples/FlashForge/CreatorPro/Configuration.h index b8378ef89a..f7e3c71190 100644 --- a/config/examples/FlashForge/CreatorPro/Configuration.h +++ b/config/examples/FlashForge/CreatorPro/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -466,7 +461,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/FlashForge/CreatorPro/Configuration_adv.h b/config/examples/FlashForge/CreatorPro/Configuration_adv.h index a31b62d2ee..b7db054010 100644 --- a/config/examples/FlashForge/CreatorPro/Configuration_adv.h +++ b/config/examples/FlashForge/CreatorPro/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/FolgerTech/i3-2020/Configuration.h b/config/examples/FolgerTech/i3-2020/Configuration.h index e24f4fbe49..6fb6795d4a 100644 --- a/config/examples/FolgerTech/i3-2020/Configuration.h +++ b/config/examples/FolgerTech/i3-2020/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 245 #define HEATER_5_MAXTEMP 245 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/FolgerTech/i3-2020/Configuration_adv.h b/config/examples/FolgerTech/i3-2020/Configuration_adv.h index 0a1c0c42e6..d6a35f40d3 100644 --- a/config/examples/FolgerTech/i3-2020/Configuration_adv.h +++ b/config/examples/FolgerTech/i3-2020/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Formbot/Raptor/Configuration.h b/config/examples/Formbot/Raptor/Configuration.h index 3ad2975b48..1ca7912ad2 100644 --- a/config/examples/Formbot/Raptor/Configuration.h +++ b/config/examples/Formbot/Raptor/Configuration.h @@ -436,7 +436,6 @@ #define TEMP_SENSOR_BED 1 #endif #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -455,8 +454,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -465,7 +462,6 @@ #define HEATER_3_MINTEMP 5 #define HEATER_4_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -480,7 +476,6 @@ #else #define BED_MAXTEMP 100 #endif -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -528,7 +523,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Formbot/Raptor/Configuration_adv.h b/config/examples/Formbot/Raptor/Configuration_adv.h index 4b0080929d..99fc0f5ee0 100644 --- a/config/examples/Formbot/Raptor/Configuration_adv.h +++ b/config/examples/Formbot/Raptor/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Formbot/T_Rex_2+/Configuration.h b/config/examples/Formbot/T_Rex_2+/Configuration.h index d406ae3bdf..864592dfe1 100644 --- a/config/examples/Formbot/T_Rex_2+/Configuration.h +++ b/config/examples/Formbot/T_Rex_2+/Configuration.h @@ -406,7 +406,6 @@ #endif #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -425,8 +424,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -436,7 +433,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -448,7 +444,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -498,7 +493,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Formbot/T_Rex_2+/Configuration_adv.h b/config/examples/Formbot/T_Rex_2+/Configuration_adv.h index ef32fde570..da1722d84b 100644 --- a/config/examples/Formbot/T_Rex_2+/Configuration_adv.h +++ b/config/examples/Formbot/T_Rex_2+/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. #define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Formbot/T_Rex_3/Configuration.h b/config/examples/Formbot/T_Rex_3/Configuration.h index 0b5e80d7d4..4ab2609e16 100644 --- a/config/examples/Formbot/T_Rex_3/Configuration.h +++ b/config/examples/Formbot/T_Rex_3/Configuration.h @@ -400,7 +400,6 @@ #endif #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -419,8 +418,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -430,7 +427,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -442,7 +438,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -485,7 +480,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Formbot/T_Rex_3/Configuration_adv.h b/config/examples/Formbot/T_Rex_3/Configuration_adv.h index b9819f2168..ef031bf0ae 100644 --- a/config/examples/Formbot/T_Rex_3/Configuration_adv.h +++ b/config/examples/Formbot/T_Rex_3/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. #define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Geeetech/A10M/Configuration.h b/config/examples/Geeetech/A10M/Configuration.h index 74107f2337..78ae286443 100644 --- a/config/examples/Geeetech/A10M/Configuration.h +++ b/config/examples/Geeetech/A10M/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -466,7 +461,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/A10M/Configuration_adv.h b/config/examples/Geeetech/A10M/Configuration_adv.h index fd1bbce4f0..b7840cc896 100644 --- a/config/examples/Geeetech/A10M/Configuration_adv.h +++ b/config/examples/Geeetech/A10M/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Geeetech/A20M/Configuration.h b/config/examples/Geeetech/A20M/Configuration.h index 0e843ec812..41521febaf 100644 --- a/config/examples/Geeetech/A20M/Configuration.h +++ b/config/examples/Geeetech/A20M/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -466,7 +461,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/A20M/Configuration_adv.h b/config/examples/Geeetech/A20M/Configuration_adv.h index 6c9217a1ce..2d868bf340 100644 --- a/config/examples/Geeetech/A20M/Configuration_adv.h +++ b/config/examples/Geeetech/A20M/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Geeetech/GT2560/Configuration.h b/config/examples/Geeetech/GT2560/Configuration.h index 12eeb3e841..bc30ce2490 100644 --- a/config/examples/Geeetech/GT2560/Configuration.h +++ b/config/examples/Geeetech/GT2560/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -486,7 +481,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h b/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h index 127604e98b..2cbb20cc5c 100644 --- a/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h +++ b/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/MeCreator2/Configuration.h b/config/examples/Geeetech/MeCreator2/Configuration.h index 6e743fbb77..32bbfb2443 100644 --- a/config/examples/Geeetech/MeCreator2/Configuration.h +++ b/config/examples/Geeetech/MeCreator2/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/MeCreator2/Configuration_adv.h b/config/examples/Geeetech/MeCreator2/Configuration_adv.h index ce1c615b09..0cf2dbf963 100644 --- a/config/examples/Geeetech/MeCreator2/Configuration_adv.h +++ b/config/examples/Geeetech/MeCreator2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h index 7eeff15cb1..5930323a66 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 125 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -486,7 +481,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h index fe1ad0d193..04e22e1018 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 125 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -486,7 +481,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h index 5ba06365d3..55f06bdab5 100644 --- a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h b/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h index f9322ca14a..4481570e44 100644 --- a/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h +++ b/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h index e9574619cf..bddc892330 100644 --- a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h b/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h index f9322ca14a..4481570e44 100644 --- a/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h +++ b/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Infitary/i3-M508/Configuration.h b/config/examples/Infitary/i3-M508/Configuration.h index 4bed2af0bc..a3dcedd901 100644 --- a/config/examples/Infitary/i3-M508/Configuration.h +++ b/config/examples/Infitary/i3-M508/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 125 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Infitary/i3-M508/Configuration_adv.h b/config/examples/Infitary/i3-M508/Configuration_adv.h index 2520c4c794..64ff999c46 100644 --- a/config/examples/Infitary/i3-M508/Configuration_adv.h +++ b/config/examples/Infitary/i3-M508/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/JGAurora/A5/Configuration.h b/config/examples/JGAurora/A5/Configuration.h index e5355499d2..8f3bc49dea 100644 --- a/config/examples/JGAurora/A5/Configuration.h +++ b/config/examples/JGAurora/A5/Configuration.h @@ -396,7 +396,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 // measured to be satisfactorily accurate on center of bed within +/- 1 degC. #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -415,8 +414,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -426,7 +423,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -438,7 +434,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -486,7 +481,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/JGAurora/A5/Configuration_adv.h b/config/examples/JGAurora/A5/Configuration_adv.h index dba7e742d0..6e42a3752e 100644 --- a/config/examples/JGAurora/A5/Configuration_adv.h +++ b/config/examples/JGAurora/A5/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/MakerParts/Configuration.h b/config/examples/MakerParts/Configuration.h index 98d3013888..9635afe50b 100644 --- a/config/examples/MakerParts/Configuration.h +++ b/config/examples/MakerParts/Configuration.h @@ -411,7 +411,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -430,8 +429,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -441,7 +438,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -453,7 +449,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -496,7 +491,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/MakerParts/Configuration_adv.h b/config/examples/MakerParts/Configuration_adv.h index eba5802a90..30283f20f4 100644 --- a/config/examples/MakerParts/Configuration_adv.h +++ b/config/examples/MakerParts/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Malyan/M150/Configuration.h b/config/examples/Malyan/M150/Configuration.h index 16f30785e0..b75cf688ee 100644 --- a/config/examples/Malyan/M150/Configuration.h +++ b/config/examples/Malyan/M150/Configuration.h @@ -399,7 +399,6 @@ // The reasons are inconclusive so I leave at 1 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -418,8 +417,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -429,7 +426,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -441,7 +437,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -484,7 +479,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Malyan/M150/Configuration_adv.h b/config/examples/Malyan/M150/Configuration_adv.h index cec4f67278..571c7026b4 100644 --- a/config/examples/Malyan/M150/Configuration_adv.h +++ b/config/examples/Malyan/M150/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Malyan/M200/Configuration.h b/config/examples/Malyan/M200/Configuration.h index aef5534b6c..fce109b27b 100644 --- a/config/examples/Malyan/M200/Configuration.h +++ b/config/examples/Malyan/M200/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 11 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 100 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -475,7 +470,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Malyan/M200/Configuration_adv.h b/config/examples/Malyan/M200/Configuration_adv.h index 70e76c5791..02e5b16e07 100644 --- a/config/examples/Malyan/M200/Configuration_adv.h +++ b/config/examples/Malyan/M200/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Micromake/C1/basic/Configuration.h b/config/examples/Micromake/C1/basic/Configuration.h index 8646d82b63..1b8d4f8733 100644 --- a/config/examples/Micromake/C1/basic/Configuration.h +++ b/config/examples/Micromake/C1/basic/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Micromake/C1/enhanced/Configuration.h b/config/examples/Micromake/C1/enhanced/Configuration.h index 79af8cfe66..04385e406f 100644 --- a/config/examples/Micromake/C1/enhanced/Configuration.h +++ b/config/examples/Micromake/C1/enhanced/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Micromake/C1/enhanced/Configuration_adv.h b/config/examples/Micromake/C1/enhanced/Configuration_adv.h index dff6e6ca1a..a7cf91eecf 100644 --- a/config/examples/Micromake/C1/enhanced/Configuration_adv.h +++ b/config/examples/Micromake/C1/enhanced/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Mks/Robin/Configuration.h b/config/examples/Mks/Robin/Configuration.h index d07a0f210d..c33b81fe57 100644 --- a/config/examples/Mks/Robin/Configuration.h +++ b/config/examples/Mks/Robin/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Mks/Robin/Configuration_adv.h b/config/examples/Mks/Robin/Configuration_adv.h index 405e236722..226d4ad0f1 100644 --- a/config/examples/Mks/Robin/Configuration_adv.h +++ b/config/examples/Mks/Robin/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Mks/Sbase/Configuration.h b/config/examples/Mks/Sbase/Configuration.h index b767a89866..a0d8278532 100644 --- a/config/examples/Mks/Sbase/Configuration.h +++ b/config/examples/Mks/Sbase/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Mks/Sbase/Configuration_adv.h b/config/examples/Mks/Sbase/Configuration_adv.h index f5ee74690c..a34b066c58 100644 --- a/config/examples/Mks/Sbase/Configuration_adv.h +++ b/config/examples/Mks/Sbase/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Printrbot/PrintrboardG2/Configuration.h b/config/examples/Printrbot/PrintrboardG2/Configuration.h index 20528942e9..146b602562 100644 --- a/config/examples/Printrbot/PrintrboardG2/Configuration.h +++ b/config/examples/Printrbot/PrintrboardG2/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/RapideLite/RL200/Configuration.h b/config/examples/RapideLite/RL200/Configuration.h index 74300e4c60..31295a053e 100644 --- a/config/examples/RapideLite/RL200/Configuration.h +++ b/config/examples/RapideLite/RL200/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/RapideLite/RL200/Configuration_adv.h b/config/examples/RapideLite/RL200/Configuration_adv.h index 7a1cf1d79f..5889db8074 100644 --- a/config/examples/RapideLite/RL200/Configuration_adv.h +++ b/config/examples/RapideLite/RL200/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/RepRapPro/Huxley/Configuration.h b/config/examples/RepRapPro/Huxley/Configuration.h index 48071ff2db..f700f548fa 100644 --- a/config/examples/RepRapPro/Huxley/Configuration.h +++ b/config/examples/RepRapPro/Huxley/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 // Sanguinololu v1.3 with 4.7kOhm pullup #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/RepRapWorld/Megatronics/Configuration.h b/config/examples/RepRapWorld/Megatronics/Configuration.h index 90f9d5be9f..3524325916 100644 --- a/config/examples/RepRapWorld/Megatronics/Configuration.h +++ b/config/examples/RepRapWorld/Megatronics/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/RigidBot/Configuration.h b/config/examples/RigidBot/Configuration.h index b24185f120..c960509189 100644 --- a/config/examples/RigidBot/Configuration.h +++ b/config/examples/RigidBot/Configuration.h @@ -394,7 +394,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -413,8 +412,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -424,7 +421,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -436,7 +432,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -479,7 +474,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/RigidBot/Configuration_adv.h b/config/examples/RigidBot/Configuration_adv.h index 6cf8a86130..2607a276b4 100644 --- a/config/examples/RigidBot/Configuration_adv.h +++ b/config/examples/RigidBot/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/SCARA/Configuration.h b/config/examples/SCARA/Configuration.h index e3bffd60df..808bc90b1f 100644 --- a/config/examples/SCARA/Configuration.h +++ b/config/examples/SCARA/Configuration.h @@ -422,7 +422,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -441,8 +440,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -452,7 +449,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -464,7 +460,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -495,7 +490,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/SCARA/Configuration_adv.h b/config/examples/SCARA/Configuration_adv.h index 165e7e59c0..ff8768107f 100644 --- a/config/examples/SCARA/Configuration_adv.h +++ b/config/examples/SCARA/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 3000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/STM32/Black_STM32F407VET6/Configuration.h b/config/examples/STM32/Black_STM32F407VET6/Configuration.h index d9067bf51d..5939baa236 100644 --- a/config/examples/STM32/Black_STM32F407VET6/Configuration.h +++ b/config/examples/STM32/Black_STM32F407VET6/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 1 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h b/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h index caf83250f1..57d21c1dfc 100644 --- a/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h +++ b/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/STM32/STM32F10/Configuration.h b/config/examples/STM32/STM32F10/Configuration.h index 87fe55272f..1d8a02a0e8 100644 --- a/config/examples/STM32/STM32F10/Configuration.h +++ b/config/examples/STM32/STM32F10/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 998 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 60 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/STM32/STM32F4/Configuration.h b/config/examples/STM32/STM32F4/Configuration.h index 935dd36b04..6055e39f44 100644 --- a/config/examples/STM32/STM32F4/Configuration.h +++ b/config/examples/STM32/STM32F4/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/STM32/stm32f103ret6/Configuration.h b/config/examples/STM32/stm32f103ret6/Configuration.h index 4348560590..5eaaceaf84 100644 --- a/config/examples/STM32/stm32f103ret6/Configuration.h +++ b/config/examples/STM32/stm32f103ret6/Configuration.h @@ -392,7 +392,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 998 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 60 @@ -411,8 +410,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -422,7 +419,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -434,7 +430,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -477,7 +472,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Sanguinololu/Configuration.h b/config/examples/Sanguinololu/Configuration.h index 861fd20991..9648c4ba38 100644 --- a/config/examples/Sanguinololu/Configuration.h +++ b/config/examples/Sanguinololu/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Sanguinololu/Configuration_adv.h b/config/examples/Sanguinololu/Configuration_adv.h index 327e47390f..e2f5b592bc 100644 --- a/config/examples/Sanguinololu/Configuration_adv.h +++ b/config/examples/Sanguinololu/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/TheBorg/Configuration.h b/config/examples/TheBorg/Configuration.h index 76bfe753ae..b86c5ad4ad 100644 --- a/config/examples/TheBorg/Configuration.h +++ b/config/examples/TheBorg/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/TheBorg/Configuration_adv.h b/config/examples/TheBorg/Configuration_adv.h index a483d4af35..f65039a92e 100644 --- a/config/examples/TheBorg/Configuration_adv.h +++ b/config/examples/TheBorg/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/TinyBoy2/Configuration.h b/config/examples/TinyBoy2/Configuration.h index ffcc2d8e84..a4dd933d37 100644 --- a/config/examples/TinyBoy2/Configuration.h +++ b/config/examples/TinyBoy2/Configuration.h @@ -418,7 +418,6 @@ #define TEMP_SENSOR_BED 0 #endif #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -437,8 +436,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -448,7 +445,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -460,7 +456,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 100 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -513,7 +508,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/TinyBoy2/Configuration_adv.h b/config/examples/TinyBoy2/Configuration_adv.h index 3b003029a9..e21e8ed5df 100644 --- a/config/examples/TinyBoy2/Configuration_adv.h +++ b/config/examples/TinyBoy2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Tronxy/X1/Configuration.h b/config/examples/Tronxy/X1/Configuration.h index 9bb197dd96..a78d57d9db 100644 --- a/config/examples/Tronxy/X1/Configuration.h +++ b/config/examples/Tronxy/X1/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Tronxy/X3A/Configuration.h b/config/examples/Tronxy/X3A/Configuration.h index ce8a3a4da1..1513d66abd 100644 --- a/config/examples/Tronxy/X3A/Configuration.h +++ b/config/examples/Tronxy/X3A/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 501 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 130 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Tronxy/X3A/Configuration_adv.h b/config/examples/Tronxy/X3A/Configuration_adv.h index f83dc8eeba..ed4be90607 100644 --- a/config/examples/Tronxy/X3A/Configuration_adv.h +++ b/config/examples/Tronxy/X3A/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Tronxy/X5S-2E/Configuration.h b/config/examples/Tronxy/X5S-2E/Configuration.h index ab4cc76fc9..a37161a280 100644 --- a/config/examples/Tronxy/X5S-2E/Configuration.h +++ b/config/examples/Tronxy/X5S-2E/Configuration.h @@ -393,7 +393,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -412,8 +411,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -423,7 +420,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -439,7 +435,6 @@ // Tronxy X5S-2E: // The OEM stock model uses a clone MK3a 300 @ 12V with no insulation and can reach a maximum 70C at 25C ambient. #define BED_MAXTEMP 81 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -489,7 +484,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Tronxy/X5S-2E/Configuration_adv.h b/config/examples/Tronxy/X5S-2E/Configuration_adv.h index d3b1c340e9..e1b54ab66e 100644 --- a/config/examples/Tronxy/X5S-2E/Configuration_adv.h +++ b/config/examples/Tronxy/X5S-2E/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Tronxy/X5S/Configuration.h b/config/examples/Tronxy/X5S/Configuration.h index 40f976bcb9..06cde48f74 100644 --- a/config/examples/Tronxy/X5S/Configuration.h +++ b/config/examples/Tronxy/X5S/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -475,7 +470,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Tronxy/XY100/Configuration.h b/config/examples/Tronxy/XY100/Configuration.h index c252b570fc..627f95c503 100644 --- a/config/examples/Tronxy/XY100/Configuration.h +++ b/config/examples/Tronxy/XY100/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -487,7 +482,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/UltiMachine/Archim1/Configuration.h b/config/examples/UltiMachine/Archim1/Configuration.h index 5aeeb3bd95..a92ad948f9 100644 --- a/config/examples/UltiMachine/Archim1/Configuration.h +++ b/config/examples/UltiMachine/Archim1/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/UltiMachine/Archim1/Configuration_adv.h b/config/examples/UltiMachine/Archim1/Configuration_adv.h index e754919433..0d8c98394c 100644 --- a/config/examples/UltiMachine/Archim1/Configuration_adv.h +++ b/config/examples/UltiMachine/Archim1/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/UltiMachine/Archim2/Configuration.h b/config/examples/UltiMachine/Archim2/Configuration.h index f835efc7d3..0411627723 100644 --- a/config/examples/UltiMachine/Archim2/Configuration.h +++ b/config/examples/UltiMachine/Archim2/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/UltiMachine/Archim2/Configuration_adv.h b/config/examples/UltiMachine/Archim2/Configuration_adv.h index 925b861338..0e03fac07b 100644 --- a/config/examples/UltiMachine/Archim2/Configuration_adv.h +++ b/config/examples/UltiMachine/Archim2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/VORONDesign/Configuration.h b/config/examples/VORONDesign/Configuration.h index 0f6f47b604..93265bf12f 100644 --- a/config/examples/VORONDesign/Configuration.h +++ b/config/examples/VORONDesign/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/VORONDesign/Configuration_adv.h b/config/examples/VORONDesign/Configuration_adv.h index 2126eb7630..652062c4f5 100644 --- a/config/examples/VORONDesign/Configuration_adv.h +++ b/config/examples/VORONDesign/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Velleman/K8200/Configuration.h b/config/examples/Velleman/K8200/Configuration.h index 6839944549..b280258ac1 100644 --- a/config/examples/Velleman/K8200/Configuration.h +++ b/config/examples/Velleman/K8200/Configuration.h @@ -411,7 +411,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -430,8 +429,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -441,7 +438,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -453,7 +449,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -500,7 +495,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Velleman/K8200/Configuration_adv.h b/config/examples/Velleman/K8200/Configuration_adv.h index b948457074..8d242aa799 100644 --- a/config/examples/Velleman/K8200/Configuration_adv.h +++ b/config/examples/Velleman/K8200/Configuration_adv.h @@ -59,6 +59,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -140,8 +153,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Velleman/K8400/Configuration.h b/config/examples/Velleman/K8400/Configuration.h index bb95b7218d..0860d62a9b 100644 --- a/config/examples/Velleman/K8400/Configuration.h +++ b/config/examples/Velleman/K8400/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Velleman/K8400/Configuration_adv.h b/config/examples/Velleman/K8400/Configuration_adv.h index 05689a1a8d..e284a534ad 100644 --- a/config/examples/Velleman/K8400/Configuration_adv.h +++ b/config/examples/Velleman/K8400/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 1000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Velleman/K8400/Dual-head/Configuration.h b/config/examples/Velleman/K8400/Dual-head/Configuration.h index 5654799872..0f50541dc2 100644 --- a/config/examples/Velleman/K8400/Dual-head/Configuration.h +++ b/config/examples/Velleman/K8400/Dual-head/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/WASP/PowerWASP/Configuration.h b/config/examples/WASP/PowerWASP/Configuration.h index d72acfc99f..bbe1529234 100644 --- a/config/examples/WASP/PowerWASP/Configuration.h +++ b/config/examples/WASP/PowerWASP/Configuration.h @@ -410,7 +410,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -429,8 +428,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -440,7 +437,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -452,7 +448,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -495,7 +490,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/WASP/PowerWASP/Configuration_adv.h b/config/examples/WASP/PowerWASP/Configuration_adv.h index 4a68eef176..f67863b5c6 100644 --- a/config/examples/WASP/PowerWASP/Configuration_adv.h +++ b/config/examples/WASP/PowerWASP/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/Wanhao/Duplicator 6/Configuration.h b/config/examples/Wanhao/Duplicator 6/Configuration.h index 3b14ba3799..ac98dac17d 100644 --- a/config/examples/Wanhao/Duplicator 6/Configuration.h +++ b/config/examples/Wanhao/Duplicator 6/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/Wanhao/Duplicator 6/Configuration_adv.h b/config/examples/Wanhao/Duplicator 6/Configuration_adv.h index da0d9f72c9..c35865bd94 100644 --- a/config/examples/Wanhao/Duplicator 6/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator 6/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/adafruit/ST7565/Configuration.h b/config/examples/adafruit/ST7565/Configuration.h index 8db4706e5b..bd72ff2bc3 100644 --- a/config/examples/adafruit/ST7565/Configuration.h +++ b/config/examples/adafruit/ST7565/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/Anycubic/Kossel/Configuration.h b/config/examples/delta/Anycubic/Kossel/Configuration.h index ec2a9d96c5..f59af6179e 100644 --- a/config/examples/delta/Anycubic/Kossel/Configuration.h +++ b/config/examples/delta/Anycubic/Kossel/Configuration.h @@ -412,7 +412,6 @@ #endif #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -431,8 +430,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -442,7 +439,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -454,7 +450,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 120 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -502,7 +497,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/Anycubic/Kossel/Configuration_adv.h b/config/examples/delta/Anycubic/Kossel/Configuration_adv.h index 811920708f..a18697673b 100644 --- a/config/examples/delta/Anycubic/Kossel/Configuration_adv.h +++ b/config/examples/delta/Anycubic/Kossel/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h index dc4ba74f3c..fab7299f5e 100644 --- a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h +++ b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h b/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h index 8717e0a0d3..1a70a19d1a 100644 --- a/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h +++ b/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/FLSUN/kossel/Configuration.h b/config/examples/delta/FLSUN/kossel/Configuration.h index cbf490cb9e..0de887940a 100644 --- a/config/examples/delta/FLSUN/kossel/Configuration.h +++ b/config/examples/delta/FLSUN/kossel/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/FLSUN/kossel/Configuration_adv.h b/config/examples/delta/FLSUN/kossel/Configuration_adv.h index 8717e0a0d3..1a70a19d1a 100644 --- a/config/examples/delta/FLSUN/kossel/Configuration_adv.h +++ b/config/examples/delta/FLSUN/kossel/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/FLSUN/kossel_mini/Configuration.h b/config/examples/delta/FLSUN/kossel_mini/Configuration.h index 2277819e7e..056e94b934 100644 --- a/config/examples/delta/FLSUN/kossel_mini/Configuration.h +++ b/config/examples/delta/FLSUN/kossel_mini/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h b/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h index fac00ef9f6..d092a4135a 100644 --- a/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h +++ b/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/Geeetech/Rostock 301/Configuration.h b/config/examples/delta/Geeetech/Rostock 301/Configuration.h index ea8120b671..29267ce80e 100644 --- a/config/examples/delta/Geeetech/Rostock 301/Configuration.h +++ b/config/examples/delta/Geeetech/Rostock 301/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h b/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h index fac00ef9f6..d092a4135a 100644 --- a/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h +++ b/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/Hatchbox_Alpha/Configuration.h b/config/examples/delta/Hatchbox_Alpha/Configuration.h index 35262a935a..59b530225b 100644 --- a/config/examples/delta/Hatchbox_Alpha/Configuration.h +++ b/config/examples/delta/Hatchbox_Alpha/Configuration.h @@ -396,7 +396,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -415,8 +414,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -426,7 +423,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -438,7 +434,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -486,7 +481,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/MKS/SBASE/Configuration.h b/config/examples/delta/MKS/SBASE/Configuration.h index 2bda8395ca..7756e40eba 100644 --- a/config/examples/delta/MKS/SBASE/Configuration.h +++ b/config/examples/delta/MKS/SBASE/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/MKS/SBASE/Configuration_adv.h b/config/examples/delta/MKS/SBASE/Configuration_adv.h index 86c6dbdc58..f369a7682b 100644 --- a/config/examples/delta/MKS/SBASE/Configuration_adv.h +++ b/config/examples/delta/MKS/SBASE/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/Tevo Little Monster/Configuration.h b/config/examples/delta/Tevo Little Monster/Configuration.h index 7c1cb2dc0e..dc9e9f22a0 100644 --- a/config/examples/delta/Tevo Little Monster/Configuration.h +++ b/config/examples/delta/Tevo Little Monster/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 1 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/Tevo Little Monster/Configuration_adv.h b/config/examples/delta/Tevo Little Monster/Configuration_adv.h index 38e80b78d9..161d038aa7 100644 --- a/config/examples/delta/Tevo Little Monster/Configuration_adv.h +++ b/config/examples/delta/Tevo Little Monster/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/generic/Configuration.h b/config/examples/delta/generic/Configuration.h index 3ef020f114..470c82c21a 100644 --- a/config/examples/delta/generic/Configuration.h +++ b/config/examples/delta/generic/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/generic/Configuration_adv.h b/config/examples/delta/generic/Configuration_adv.h index fac00ef9f6..d092a4135a 100644 --- a/config/examples/delta/generic/Configuration_adv.h +++ b/config/examples/delta/generic/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/kossel_mini/Configuration.h b/config/examples/delta/kossel_mini/Configuration.h index 31ab8f5085..181f699ec5 100644 --- a/config/examples/delta/kossel_mini/Configuration.h +++ b/config/examples/delta/kossel_mini/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 11 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/kossel_mini/Configuration_adv.h b/config/examples/delta/kossel_mini/Configuration_adv.h index e3daa9b375..4b078e8d7c 100644 --- a/config/examples/delta/kossel_mini/Configuration_adv.h +++ b/config/examples/delta/kossel_mini/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/delta/kossel_pro/Configuration.h b/config/examples/delta/kossel_pro/Configuration.h index c139478cda..75fa32ee6e 100644 --- a/config/examples/delta/kossel_pro/Configuration.h +++ b/config/examples/delta/kossel_pro/Configuration.h @@ -395,7 +395,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -414,8 +413,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -425,7 +422,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -437,7 +433,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -468,7 +463,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/kossel_xl/Configuration.h b/config/examples/delta/kossel_xl/Configuration.h index 5649229a5b..a21d21d9ec 100644 --- a/config/examples/delta/kossel_xl/Configuration.h +++ b/config/examples/delta/kossel_xl/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -480,7 +475,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/delta/kossel_xl/Configuration_adv.h b/config/examples/delta/kossel_xl/Configuration_adv.h index d4c3eb599a..50bf1ab510 100644 --- a/config/examples/delta/kossel_xl/Configuration_adv.h +++ b/config/examples/delta/kossel_xl/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/gCreate/gMax1.5+/Configuration.h b/config/examples/gCreate/gMax1.5+/Configuration.h index 05ddccd0a6..b71bf23935 100644 --- a/config/examples/gCreate/gMax1.5+/Configuration.h +++ b/config/examples/gCreate/gMax1.5+/Configuration.h @@ -399,7 +399,6 @@ // a Fortek SSR to do it. If you are using an unaltered gCreate machine, this needs // to be set to 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -418,8 +417,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -429,7 +426,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -441,7 +437,6 @@ #define HEATER_4_MAXTEMP 245 #define HEATER_5_MAXTEMP 245 #define BED_MAXTEMP 115 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -489,7 +484,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/gCreate/gMax1.5+/Configuration_adv.h b/config/examples/gCreate/gMax1.5+/Configuration_adv.h index b476cd19cc..49165c0d41 100644 --- a/config/examples/gCreate/gMax1.5+/Configuration_adv.h +++ b/config/examples/gCreate/gMax1.5+/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/makibox/Configuration.h b/config/examples/makibox/Configuration.h index 7abbf252c1..c19ba37b01 100644 --- a/config/examples/makibox/Configuration.h +++ b/config/examples/makibox/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 12 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -476,7 +471,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/makibox/Configuration_adv.h b/config/examples/makibox/Configuration_adv.h index e1c2e688bd..31fb062a48 100644 --- a/config/examples/makibox/Configuration_adv.h +++ b/config/examples/makibox/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/tvrrug/Round2/Configuration.h b/config/examples/tvrrug/Round2/Configuration.h index 5fb5a512ae..7cd185a3af 100644 --- a/config/examples/tvrrug/Round2/Configuration.h +++ b/config/examples/tvrrug/Round2/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 5 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -465,7 +460,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/tvrrug/Round2/Configuration_adv.h b/config/examples/tvrrug/Round2/Configuration_adv.h index ae18ae28c4..26f2fb89b2 100644 --- a/config/examples/tvrrug/Round2/Configuration_adv.h +++ b/config/examples/tvrrug/Round2/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) diff --git a/config/examples/wt150/Configuration.h b/config/examples/wt150/Configuration.h index 4b5fa0251b..8a0b0401cb 100644 --- a/config/examples/wt150/Configuration.h +++ b/config/examples/wt150/Configuration.h @@ -391,7 +391,6 @@ #define TEMP_SENSOR_5 0 #define TEMP_SENSOR_BED 0 #define TEMP_SENSOR_CHAMBER 0 -#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system // Dummy thermistor constant temperature readings, for use with 998 and 999 #define DUMMY_THERMISTOR_998_VALUE 25 @@ -410,8 +409,6 @@ #define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer #define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target - // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire. #define HEATER_0_MINTEMP 5 @@ -421,7 +418,6 @@ #define HEATER_4_MINTEMP 5 #define HEATER_5_MINTEMP 5 #define BED_MINTEMP 5 -#define CHAMBER_MINTEMP 5 // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. @@ -433,7 +429,6 @@ #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 #define BED_MAXTEMP 150 -#define CHAMBER_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ @@ -481,7 +476,7 @@ #endif // PIDTEMP //=========================================================================== -//============================= PID > Bed Temperature Control =============== +//====================== PID > Bed Temperature Control ====================== //=========================================================================== /** diff --git a/config/examples/wt150/Configuration_adv.h b/config/examples/wt150/Configuration_adv.h index 2c4027bc9d..22cd224d65 100644 --- a/config/examples/wt150/Configuration_adv.h +++ b/config/examples/wt150/Configuration_adv.h @@ -50,6 +50,19 @@ #define HEATER_BED_INVERTING true #endif +/** + * Heated Chamber settings + */ +#if TEMP_SENSOR_CHAMBER + #define CHAMBER_MINTEMP 5 + #define CHAMBER_MAXTEMP 60 + #define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target + #define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber + //#define CHAMBER_LIMIT_SWITCHING + //#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin + //#define HEATER_CHAMBER_INVERTING false +#endif + #if DISABLED(PIDTEMPBED) #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control #if ENABLED(BED_LIMIT_SWITCHING) @@ -127,8 +140,8 @@ #endif #if ENABLED(PIDTEMP) - // this adds an experimental additional term to the heating power, proportional to the extrusion speed. - // if Kc is chosen well, the additional required power due to increased melting should be compensated. + // Add an experimental additional term to the heater power, proportional to the extrusion speed. + // A well-chosen Kc value should add just enough power to melt the increased material volume. //#define PID_EXTRUSION_SCALING #if ENABLED(PID_EXTRUSION_SCALING) #define DEFAULT_Kc (100) //heating power=Kc*(e_speed)