Merge pull request #3284 from thinkyhead/rc_stop_watchheat_lcdset0
Fix temperature checking conditions (backwards!)
This commit is contained in:
commit
8def2c31db
|
@ -4265,7 +4265,7 @@ inline void gcode_M109() {
|
|||
#define TEMP_CONDITIONS (residency_start_ms < 0 || now < residency_start_ms + (TEMP_RESIDENCY_TIME) * 1000UL)
|
||||
#else
|
||||
// Loop until the temperature is very close target
|
||||
#define TEMP_CONDITIONS (fabs(degHotend(target_extruder) - degTargetHotend(target_extruder)) < 0.75f)
|
||||
#define TEMP_CONDITIONS (isHeatingHotend(target_extruder))
|
||||
#endif //TEMP_RESIDENCY_TIME
|
||||
|
||||
cancel_heatup = false;
|
||||
|
@ -4325,7 +4325,7 @@ inline void gcode_M109() {
|
|||
|
||||
cancel_heatup = false;
|
||||
millis_t now = millis(), next_temp_ms = now + 1000UL;
|
||||
while (!cancel_heatup && fabs(degTargetBed() - degBed()) < 0.75f) {
|
||||
while (!cancel_heatup && isHeatingBed()) {
|
||||
millis_t now = millis();
|
||||
if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up.
|
||||
next_temp_ms = now + 1000UL;
|
||||
|
|
Loading…
Reference in a new issue