Print timer now stops when it sees the last extruder temperature being shutdown
This commit is contained in:
parent
b7928a000a
commit
986b508ff7
|
@ -3833,6 +3833,19 @@ inline void gcode_M104() {
|
||||||
setTargetHotend1(temp == 0.0 ? 0.0 : temp + duplicate_extruder_temp_offset);
|
setTargetHotend1(temp == 0.0 ? 0.0 : temp + duplicate_extruder_temp_offset);
|
||||||
#endif
|
#endif
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Detect if a print job has finished.
|
||||||
|
// When the target temperature for all extruders is zero then we must have
|
||||||
|
// finished printing.
|
||||||
|
if( print_job_start_ms != 0 ) {
|
||||||
|
bool all_extruders_cooling = true;
|
||||||
|
for (int i = 0; i < EXTRUDERS; i++) if( degTargetHotend(i) > 0 ) {
|
||||||
|
all_extruders_cooling = false;
|
||||||
|
break;
|
||||||
|
}
|
||||||
|
|
||||||
|
if( all_extruders_cooling ) print_job_stop_ms = millis();
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
#if HAS_TEMP_0 || HAS_TEMP_BED || ENABLED(HEATER_0_USES_MAX6675)
|
#if HAS_TEMP_0 || HAS_TEMP_BED || ENABLED(HEATER_0_USES_MAX6675)
|
||||||
|
@ -3944,16 +3957,15 @@ inline void gcode_M105() {
|
||||||
* Rxxx Wait for extruder(s) to reach temperature. Waits when heating and cooling.
|
* Rxxx Wait for extruder(s) to reach temperature. Waits when heating and cooling.
|
||||||
*/
|
*/
|
||||||
inline void gcode_M109() {
|
inline void gcode_M109() {
|
||||||
|
float temp;
|
||||||
bool no_wait_for_cooling = true;
|
bool no_wait_for_cooling = true;
|
||||||
|
|
||||||
if (setTargetedHotend(109)) return;
|
if (setTargetedHotend(109)) return;
|
||||||
if (marlin_debug_flags & DEBUG_DRYRUN) return;
|
if (marlin_debug_flags & DEBUG_DRYRUN) return;
|
||||||
|
|
||||||
LCD_MESSAGEPGM(MSG_HEATING);
|
|
||||||
|
|
||||||
no_wait_for_cooling = code_seen('S');
|
no_wait_for_cooling = code_seen('S');
|
||||||
if (no_wait_for_cooling || code_seen('R')) {
|
if (no_wait_for_cooling || code_seen('R')) {
|
||||||
float temp = code_value();
|
temp = code_value();
|
||||||
setTargetHotend(temp, target_extruder);
|
setTargetHotend(temp, target_extruder);
|
||||||
#if ENABLED(DUAL_X_CARRIAGE)
|
#if ENABLED(DUAL_X_CARRIAGE)
|
||||||
if (dual_x_carriage_mode == DXC_DUPLICATION_MODE && target_extruder == 0)
|
if (dual_x_carriage_mode == DXC_DUPLICATION_MODE && target_extruder == 0)
|
||||||
|
@ -3961,6 +3973,9 @@ inline void gcode_M109() {
|
||||||
#endif
|
#endif
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Only makes sense to show the heating message if we're in fact heating.
|
||||||
|
if( temp > 0 ) LCD_MESSAGEPGM(MSG_HEATING);
|
||||||
|
|
||||||
#if ENABLED(AUTOTEMP)
|
#if ENABLED(AUTOTEMP)
|
||||||
autotemp_enabled = code_seen('F');
|
autotemp_enabled = code_seen('F');
|
||||||
if (autotemp_enabled) autotemp_factor = code_value();
|
if (autotemp_enabled) autotemp_factor = code_value();
|
||||||
|
@ -3968,6 +3983,22 @@ inline void gcode_M109() {
|
||||||
if (code_seen('B')) autotemp_max = code_value();
|
if (code_seen('B')) autotemp_max = code_value();
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
// Detect if a print job has finished.
|
||||||
|
// When the target temperature for all extruders is zero then we must have
|
||||||
|
// finished printing.
|
||||||
|
if( print_job_start_ms != 0 ) {
|
||||||
|
bool all_extruders_cooling = true;
|
||||||
|
for (int i = 0; i < EXTRUDERS; i++) if( degTargetHotend(i) > 0 ) {
|
||||||
|
all_extruders_cooling = false;
|
||||||
|
break;
|
||||||
|
}
|
||||||
|
|
||||||
|
if( all_extruders_cooling ) {
|
||||||
|
print_job_stop_ms = millis();
|
||||||
|
LCD_MESSAGEPGM(WELCOME_MSG);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
// Exit if the temperature is above target and not waiting for cooling
|
// Exit if the temperature is above target and not waiting for cooling
|
||||||
if (no_wait_for_cooling && !isHeatingHotend(target_extruder)) return;
|
if (no_wait_for_cooling && !isHeatingHotend(target_extruder)) return;
|
||||||
|
|
||||||
|
|
|
@ -306,7 +306,8 @@ static void lcd_implementation_status_screen() {
|
||||||
|
|
||||||
u8g.setPrintPos(80,48);
|
u8g.setPrintPos(80,48);
|
||||||
if (print_job_start_ms != 0) {
|
if (print_job_start_ms != 0) {
|
||||||
uint16_t time = (millis() - print_job_start_ms) / 60000;
|
uint16_t time = ((print_job_stop_ms > print_job_start_ms)
|
||||||
|
? print_job_stop_ms : millis()) / 60000 - print_job_start_ms / 60000;
|
||||||
lcd_print(itostr2(time/60));
|
lcd_print(itostr2(time/60));
|
||||||
lcd_print(':');
|
lcd_print(':');
|
||||||
lcd_print(itostr2(time%60));
|
lcd_print(itostr2(time%60));
|
||||||
|
|
|
@ -1111,6 +1111,9 @@ void disable_all_heaters() {
|
||||||
for (int i = 0; i < EXTRUDERS; i++) setTargetHotend(0, i);
|
for (int i = 0; i < EXTRUDERS; i++) setTargetHotend(0, i);
|
||||||
setTargetBed(0);
|
setTargetBed(0);
|
||||||
|
|
||||||
|
// If all heaters go down then for sure our print job has stopped
|
||||||
|
if( print_job_start_ms != 0 ) print_job_stop_ms = millis();
|
||||||
|
|
||||||
#define DISABLE_HEATER(NR) { \
|
#define DISABLE_HEATER(NR) { \
|
||||||
target_temperature[NR] = 0; \
|
target_temperature[NR] = 0; \
|
||||||
soft_pwm[NR] = 0; \
|
soft_pwm[NR] = 0; \
|
||||||
|
|
|
@ -707,7 +707,8 @@ static void lcd_implementation_status_screen() {
|
||||||
lcd.setCursor(LCD_WIDTH - 6, 2);
|
lcd.setCursor(LCD_WIDTH - 6, 2);
|
||||||
lcd.print(LCD_STR_CLOCK[0]);
|
lcd.print(LCD_STR_CLOCK[0]);
|
||||||
if (print_job_start_ms != 0) {
|
if (print_job_start_ms != 0) {
|
||||||
uint16_t time = millis() / 60000 - print_job_start_ms / 60000;
|
uint16_t time = ((print_job_stop_ms > print_job_start_ms)
|
||||||
|
? print_job_stop_ms : millis()) / 60000 - print_job_start_ms / 60000;
|
||||||
lcd.print(itostr2(time / 60));
|
lcd.print(itostr2(time / 60));
|
||||||
lcd.print(':');
|
lcd.print(':');
|
||||||
lcd.print(itostr2(time % 60));
|
lcd.print(itostr2(time % 60));
|
||||||
|
|
Loading…
Reference in a new issue