Capitalize "G-code"
This commit is contained in:
parent
8f725e25b5
commit
b6051efe5b
|
@ -2213,7 +2213,7 @@
|
|||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// SkeinForge sends the wrong arc g-codes when using Arc Point as fillet procedure
|
||||
// SkeinForge sends the wrong arc G-codes when using Arc Point as fillet procedure
|
||||
//#define SF_ARC_FIX
|
||||
|
||||
// Support for the BariCUDA Paste Extruder
|
||||
|
|
|
@ -1186,7 +1186,7 @@
|
|||
#if ENABLED(SDCARD_SORT_ALPHA)
|
||||
#define SDSORT_LIMIT 40 // Maximum number of sorted items (10-256). Costs 27 bytes each.
|
||||
#define FOLDER_SORTING -1 // -1=above 0=none 1=below
|
||||
#define SDSORT_GCODE false // Allow turning sorting on/off with LCD and M34 g-code.
|
||||
#define SDSORT_GCODE false // Allow turning sorting on/off with LCD and M34 G-code.
|
||||
#define SDSORT_USES_RAM false // Pre-allocate a static array for faster pre-sorting.
|
||||
#define SDSORT_USES_STACK false // Prefer the stack for pre-sorting to give back some SRAM. (Negated by next 2 options.)
|
||||
#define SDSORT_CACHE_NAMES false // Keep sorted items in RAM longer for speedy performance. Most expensive option.
|
||||
|
@ -2424,7 +2424,7 @@
|
|||
* for error conditions like overtemperature and short to ground.
|
||||
* To manage over-temp Marlin can decrease the driver current until the error condition clears.
|
||||
* Other detected conditions can be used to stop the current print.
|
||||
* Relevant g-codes:
|
||||
* Relevant G-codes:
|
||||
* M906 - Set or get motor current in milliamps using axis codes X, Y, Z, E. Report values if no axis codes given.
|
||||
* M911 - Report stepper driver overtemperature pre-warn condition.
|
||||
* M912 - Clear stepper driver overtemperature pre-warn condition flag.
|
||||
|
@ -2715,7 +2715,7 @@
|
|||
* Monitor L6470 drivers for error conditions like over temperature and over current.
|
||||
* In the case of over temperature Marlin can decrease the drive until the error condition clears.
|
||||
* Other detected conditions can be used to stop the current print.
|
||||
* Relevant g-codes:
|
||||
* Relevant G-codes:
|
||||
* M906 - I1/2/3/4/5 Set or get motor drive level using axis codes X, Y, Z, E. Report values if no axis codes given.
|
||||
* I not present or I0 or I1 - X, Y, Z or E0
|
||||
* I2 - X2, Y2, Z2 or E1
|
||||
|
|
Loading…
Reference in a new issue