M109 and M190 now wait when cooling down if R is used instead of S.
M109 S180 waits only when heating. M109 R180 also waits when cooling.
This commit is contained in:
parent
8a2a3ef91d
commit
c4a2077951
|
@ -259,11 +259,11 @@
|
||||||
|
|
||||||
#ifndef ENDSTOPPULLUPS
|
#ifndef ENDSTOPPULLUPS
|
||||||
// fine Enstop settings: Individual Pullups. will be ignored if ENDSTOPPULLUPS is defined
|
// fine Enstop settings: Individual Pullups. will be ignored if ENDSTOPPULLUPS is defined
|
||||||
#define ENDSTOPPULLUP_XMAX
|
// #define ENDSTOPPULLUP_XMAX
|
||||||
#define ENDSTOPPULLUP_YMAX
|
// #define ENDSTOPPULLUP_YMAX
|
||||||
#define ENDSTOPPULLUP_ZMAX
|
// #define ENDSTOPPULLUP_ZMAX
|
||||||
#define ENDSTOPPULLUP_XMIN
|
// #define ENDSTOPPULLUP_XMIN
|
||||||
#define ENDSTOPPULLUP_YMIN
|
// #define ENDSTOPPULLUP_YMIN
|
||||||
// #define ENDSTOPPULLUP_ZMIN
|
// #define ENDSTOPPULLUP_ZMIN
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
|
|
@ -18,12 +18,6 @@
|
||||||
//#define WATCH_TEMP_PERIOD 40000 //40 seconds
|
//#define WATCH_TEMP_PERIOD 40000 //40 seconds
|
||||||
//#define WATCH_TEMP_INCREASE 10 //Heat up at least 10 degree in 20 seconds
|
//#define WATCH_TEMP_INCREASE 10 //Heat up at least 10 degree in 20 seconds
|
||||||
|
|
||||||
// Wait for Cooldown
|
|
||||||
// This defines if the M109 call should not block if it is cooling down.
|
|
||||||
// example: From a current temp of 220, you set M109 S200.
|
|
||||||
// if CooldownNoWait is defined M109 will not wait for the cooldown to finish
|
|
||||||
#define CooldownNoWait true
|
|
||||||
|
|
||||||
#ifdef PIDTEMP
|
#ifdef PIDTEMP
|
||||||
// this adds an experimental additional term to the heatingpower, proportional to the extrusion speed.
|
// this adds an experimental additional term to the heatingpower, proportional to the extrusion speed.
|
||||||
// if Kc is choosen well, the additional required power due to increased melting should be compensated.
|
// if Kc is choosen well, the additional required power due to increased melting should be compensated.
|
||||||
|
|
|
@ -67,17 +67,9 @@
|
||||||
// G91 - Use Relative Coordinates
|
// G91 - Use Relative Coordinates
|
||||||
// G92 - Set current position to cordinates given
|
// G92 - Set current position to cordinates given
|
||||||
|
|
||||||
//RepRap M Codes
|
// M Codes
|
||||||
// M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
|
// M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
|
||||||
// M1 - Same as M0
|
// M1 - Same as M0
|
||||||
// M104 - Set extruder target temp
|
|
||||||
// M105 - Read current temp
|
|
||||||
// M106 - Fan on
|
|
||||||
// M107 - Fan off
|
|
||||||
// M109 - Wait for extruder current temp to reach target temp.
|
|
||||||
// M114 - Display current position
|
|
||||||
|
|
||||||
//Custom M Codes
|
|
||||||
// M17 - Enable/Power all stepper motors
|
// M17 - Enable/Power all stepper motors
|
||||||
// M18 - Disable all stepper motors; same as M84
|
// M18 - Disable all stepper motors; same as M84
|
||||||
// M20 - List SD card
|
// M20 - List SD card
|
||||||
|
@ -101,6 +93,12 @@
|
||||||
// or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
|
// or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
|
||||||
// M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
|
// M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
|
||||||
// M92 - Set axis_steps_per_unit - same syntax as G92
|
// M92 - Set axis_steps_per_unit - same syntax as G92
|
||||||
|
// M104 - Set extruder target temp
|
||||||
|
// M105 - Read current temp
|
||||||
|
// M106 - Fan on
|
||||||
|
// M107 - Fan off
|
||||||
|
// M109 - Sxxx Wait for extruder current temp to reach target temp. Waits only when heating
|
||||||
|
// Rxxx Wait for extruder current temp to reach target temp. Waits when heating and cooling
|
||||||
// M114 - Output current position to serial port
|
// M114 - Output current position to serial port
|
||||||
// M115 - Capabilities string
|
// M115 - Capabilities string
|
||||||
// M117 - display message
|
// M117 - display message
|
||||||
|
@ -110,7 +108,8 @@
|
||||||
// M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
// M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
||||||
// M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
// M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
||||||
// M140 - Set bed target temp
|
// M140 - Set bed target temp
|
||||||
// M190 - Wait for bed current temp to reach target temp.
|
// M190 - Sxxx Wait for bed current temp to reach target temp. Waits only when heating
|
||||||
|
// Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
|
||||||
// M200 - Set filament diameter
|
// M200 - Set filament diameter
|
||||||
// M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
|
// M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
|
||||||
// M202 - Set max acceleration in units/s^2 for travel moves (M202 X1000 Y1000) Unused in Marlin!!
|
// M202 - Set max acceleration in units/s^2 for travel moves (M202 X1000 Y1000) Unused in Marlin!!
|
||||||
|
@ -242,6 +241,9 @@ bool Stopped=false;
|
||||||
Servo servos[NUM_SERVOS];
|
Servo servos[NUM_SERVOS];
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
bool CooldownNoWait = true;
|
||||||
|
bool target_direction;
|
||||||
|
|
||||||
//===========================================================================
|
//===========================================================================
|
||||||
//=============================ROUTINES=============================
|
//=============================ROUTINES=============================
|
||||||
//===========================================================================
|
//===========================================================================
|
||||||
|
@ -1161,7 +1163,13 @@ void process_commands()
|
||||||
#ifdef AUTOTEMP
|
#ifdef AUTOTEMP
|
||||||
autotemp_enabled=false;
|
autotemp_enabled=false;
|
||||||
#endif
|
#endif
|
||||||
if (code_seen('S')) setTargetHotend(code_value(), tmp_extruder);
|
if (code_seen('S')) {
|
||||||
|
setTargetHotend(code_value(), tmp_extruder);
|
||||||
|
CooldownNoWait = true;
|
||||||
|
} else if (code_seen('R')) {
|
||||||
|
setTargetHotend(code_value(), tmp_extruder);
|
||||||
|
CooldownNoWait = false;
|
||||||
|
}
|
||||||
#ifdef AUTOTEMP
|
#ifdef AUTOTEMP
|
||||||
if (code_seen('S')) autotemp_min=code_value();
|
if (code_seen('S')) autotemp_min=code_value();
|
||||||
if (code_seen('B')) autotemp_max=code_value();
|
if (code_seen('B')) autotemp_max=code_value();
|
||||||
|
@ -1176,7 +1184,7 @@ void process_commands()
|
||||||
codenum = millis();
|
codenum = millis();
|
||||||
|
|
||||||
/* See if we are heating up or cooling down */
|
/* See if we are heating up or cooling down */
|
||||||
bool target_direction = isHeatingHotend(tmp_extruder); // true if heating, false if cooling
|
target_direction = isHeatingHotend(tmp_extruder); // true if heating, false if cooling
|
||||||
|
|
||||||
#ifdef TEMP_RESIDENCY_TIME
|
#ifdef TEMP_RESIDENCY_TIME
|
||||||
long residencyStart;
|
long residencyStart;
|
||||||
|
@ -1232,9 +1240,18 @@ void process_commands()
|
||||||
case 190: // M190 - Wait for bed heater to reach target.
|
case 190: // M190 - Wait for bed heater to reach target.
|
||||||
#if defined(TEMP_BED_PIN) && TEMP_BED_PIN > -1
|
#if defined(TEMP_BED_PIN) && TEMP_BED_PIN > -1
|
||||||
LCD_MESSAGEPGM(MSG_BED_HEATING);
|
LCD_MESSAGEPGM(MSG_BED_HEATING);
|
||||||
if (code_seen('S')) setTargetBed(code_value());
|
if (code_seen('S')) {
|
||||||
|
setTargetBed(code_value());
|
||||||
|
CooldownNoWait = true;
|
||||||
|
} else if (code_seen('R')) {
|
||||||
|
setTargetBed(code_value());
|
||||||
|
CooldownNoWait = false;
|
||||||
|
}
|
||||||
codenum = millis();
|
codenum = millis();
|
||||||
while(isHeatingBed())
|
|
||||||
|
target_direction = isHeatingBed(); // true if heating, false if cooling
|
||||||
|
|
||||||
|
while ( target_direction ? (isHeatingBed()) : (isCoolingBed()&&(CooldownNoWait==false)) )
|
||||||
{
|
{
|
||||||
if(( millis() - codenum) > 1000 ) //Print Temp Reading every 1 second while heating up.
|
if(( millis() - codenum) > 1000 ) //Print Temp Reading every 1 second while heating up.
|
||||||
{
|
{
|
||||||
|
|
19
README.md
19
README.md
|
@ -142,17 +142,9 @@ Implemented G Codes:
|
||||||
* G91 - Use Relative Coordinates
|
* G91 - Use Relative Coordinates
|
||||||
* G92 - Set current position to cordinates given
|
* G92 - Set current position to cordinates given
|
||||||
|
|
||||||
RepRap M Codes
|
M Codes
|
||||||
* M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
|
* M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
|
||||||
* M1 - Same as M0
|
* M1 - Same as M0
|
||||||
* M104 - Set extruder target temp
|
|
||||||
* M105 - Read current temp
|
|
||||||
* M106 - Fan on
|
|
||||||
* M107 - Fan off
|
|
||||||
* M109 - Wait for extruder current temp to reach target temp.
|
|
||||||
* M114 - Display current position
|
|
||||||
|
|
||||||
Custom M Codes
|
|
||||||
* M17 - Enable/Power all stepper motors
|
* M17 - Enable/Power all stepper motors
|
||||||
* M18 - Disable all stepper motors; same as M84
|
* M18 - Disable all stepper motors; same as M84
|
||||||
* M20 - List SD card
|
* M20 - List SD card
|
||||||
|
@ -175,6 +167,12 @@ Custom M Codes
|
||||||
* M84 - Disable steppers until next move, or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
|
* M84 - Disable steppers until next move, or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
|
||||||
* M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
|
* M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
|
||||||
* M92 - Set axis_steps_per_unit - same syntax as G92
|
* M92 - Set axis_steps_per_unit - same syntax as G92
|
||||||
|
* M104 - Set extruder target temp
|
||||||
|
* M105 - Read current temp
|
||||||
|
* M106 - Fan on
|
||||||
|
* M107 - Fan off
|
||||||
|
* M109 - Sxxx Wait for extruder current temp to reach target temp. Waits only when heating
|
||||||
|
* Rxxx Wait for extruder current temp to reach target temp. Waits when heating and cooling
|
||||||
* M114 - Output current position to serial port
|
* M114 - Output current position to serial port
|
||||||
* M115 - Capabilities string
|
* M115 - Capabilities string
|
||||||
* M117 - display message
|
* M117 - display message
|
||||||
|
@ -184,7 +182,8 @@ Custom M Codes
|
||||||
* M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
* M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
||||||
* M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
* M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
|
||||||
* M140 - Set bed target temp
|
* M140 - Set bed target temp
|
||||||
* M190 - Wait for bed current temp to reach target temp.
|
* M190 - Sxxx Wait for bed current temp to reach target temp. Waits only when heating
|
||||||
|
* Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
|
||||||
* M200 - Set filament diameter
|
* M200 - Set filament diameter
|
||||||
* M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
|
* M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
|
||||||
* M202 - Set max acceleration in units/s^2 for travel moves (M202 X1000 Y1000) Unused in Marlin!!
|
* M202 - Set max acceleration in units/s^2 for travel moves (M202 X1000 Y1000) Unused in Marlin!!
|
||||||
|
|
Loading…
Reference in a new issue