Merge pull request #1825 from shaggythesheep/bugfix_no_heaters
Bugfix: Temperature checks when no heaters in use
This commit is contained in:
commit
d05efa008d
|
@ -1525,15 +1525,17 @@ ISR(TIMER0_COMPB_vect) {
|
|||
for (int i = 0; i < 4; i++) raw_temp_value[i] = 0;
|
||||
raw_temp_bed_value = 0;
|
||||
|
||||
#ifndef HEATER_0_USES_MAX6675
|
||||
#if HEATER_0_RAW_LO_TEMP > HEATER_0_RAW_HI_TEMP
|
||||
#define GE0 <=
|
||||
#else
|
||||
#define GE0 >=
|
||||
#endif
|
||||
if (current_temperature_raw[0] GE0 maxttemp_raw[0]) max_temp_error(0);
|
||||
if (minttemp_raw[0] GE0 current_temperature_raw[0]) min_temp_error(0);
|
||||
#endif
|
||||
#if HAS_TEMP_0
|
||||
#ifndef HEATER_0_USES_MAX6675
|
||||
#if HEATER_0_RAW_LO_TEMP > HEATER_0_RAW_HI_TEMP
|
||||
#define GE0 <=
|
||||
#else
|
||||
#define GE0 >=
|
||||
#endif
|
||||
if (current_temperature_raw[0] GE0 maxttemp_raw[0]) max_temp_error(0);
|
||||
if (minttemp_raw[0] GE0 current_temperature_raw[0]) min_temp_error(0);
|
||||
#endif
|
||||
#endif
|
||||
|
||||
#if HAS_TEMP_1
|
||||
#if HEATER_1_RAW_LO_TEMP > HEATER_1_RAW_HI_TEMP
|
||||
|
|
Loading…
Reference in a new issue