Drop extra Bed PID
This commit is contained in:
parent
4975e93350
commit
dd118e2f36
|
@ -532,18 +532,12 @@
|
|||
//#define MIN_BED_POWER 0
|
||||
//#define PID_BED_DEBUG // Sends debug data to the serial port.
|
||||
|
||||
//120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
||||
//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
|
||||
// 120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
||||
// from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
|
||||
#define DEFAULT_bedKp 10.00
|
||||
#define DEFAULT_bedKi .023
|
||||
#define DEFAULT_bedKd 305.4
|
||||
|
||||
//120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
||||
//from pidautotune
|
||||
//#define DEFAULT_bedKp 97.1
|
||||
//#define DEFAULT_bedKi 1.41
|
||||
//#define DEFAULT_bedKd 1675.16
|
||||
|
||||
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
|
||||
#endif // PIDTEMPBED
|
||||
|
||||
|
|
|
@ -3473,7 +3473,7 @@
|
|||
*/
|
||||
//#define MMU_EXTRUDER_SENSOR
|
||||
#if ENABLED(MMU_EXTRUDER_SENSOR)
|
||||
#define MMU_LOADING_ATTEMPTS_NR 5 //max. number of attempts to load filament if first load fail
|
||||
#define MMU_LOADING_ATTEMPTS_NR 5 // max. number of attempts to load filament if first load fail
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
|