Fix ABL G29 early BLTouch deploy
This commit is contained in:
parent
c60600ebb9
commit
fac3a7d147
|
@ -78,11 +78,7 @@
|
|||
#endif
|
||||
#endif
|
||||
|
||||
#if ENABLED(G29_RETRY_AND_RECOVER)
|
||||
#define G29_RETURN(b) return b;
|
||||
#else
|
||||
#define G29_RETURN(b) return;
|
||||
#endif
|
||||
#define G29_RETURN(b) return TERN_(G29_RETRY_AND_RECOVER, b)
|
||||
|
||||
/**
|
||||
* G29: Detailed Z probe, probes the bed at 3 or more points.
|
||||
|
@ -164,11 +160,7 @@
|
|||
*/
|
||||
G29_TYPE GcodeSuite::G29() {
|
||||
|
||||
#if EITHER(DEBUG_LEVELING_FEATURE, PROBE_MANUALLY)
|
||||
const bool seenQ = parser.seen('Q');
|
||||
#else
|
||||
constexpr bool seenQ = false;
|
||||
#endif
|
||||
const bool seenQ = EITHER(DEBUG_LEVELING_FEATURE, PROBE_MANUALLY) && parser.seen('Q');
|
||||
|
||||
// G29 Q is also available if debugging
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
|
@ -179,25 +171,12 @@ G29_TYPE GcodeSuite::G29() {
|
|||
log_machine_info();
|
||||
}
|
||||
marlin_debug_flags = old_debug_flags;
|
||||
#if DISABLED(PROBE_MANUALLY)
|
||||
if (seenQ) G29_RETURN(false);
|
||||
#endif
|
||||
if (DISABLED(PROBE_MANUALLY) && seenQ) G29_RETURN(false);
|
||||
#endif
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
const bool seenA = parser.seen('A');
|
||||
#else
|
||||
constexpr bool seenA = false;
|
||||
#endif
|
||||
|
||||
const bool no_action = seenA || seenQ,
|
||||
faux =
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE) && DISABLED(PROBE_MANUALLY)
|
||||
parser.boolval('C')
|
||||
#else
|
||||
no_action
|
||||
#endif
|
||||
;
|
||||
const bool seenA = TERN0(PROBE_MANUALLY, parser.seen('A')),
|
||||
no_action = seenA || seenQ,
|
||||
faux = ENABLED(DEBUG_LEVELING_FEATURE) && DISABLED(PROBE_MANUALLY) ? parser.boolval('C') : no_action;
|
||||
|
||||
// Don't allow auto-leveling without homing first
|
||||
if (axis_unhomed_error()) G29_RETURN(false);
|
||||
|
@ -208,11 +187,7 @@ G29_TYPE GcodeSuite::G29() {
|
|||
}
|
||||
|
||||
// Define local vars 'static' for manual probing, 'auto' otherwise
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
#define ABL_VAR static
|
||||
#else
|
||||
#define ABL_VAR
|
||||
#endif
|
||||
#define ABL_VAR TERN_(PROBE_MANUALLY, static)
|
||||
|
||||
ABL_VAR int verbose_level;
|
||||
ABL_VAR xy_pos_t probePos;
|
||||
|
@ -346,11 +321,7 @@ G29_TYPE GcodeSuite::G29() {
|
|||
G29_RETURN(false);
|
||||
}
|
||||
|
||||
dryrun = parser.boolval('D')
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
|| no_action
|
||||
#endif
|
||||
;
|
||||
dryrun = parser.boolval('D') || TERN0(PROBE_MANUALLY, no_action);
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
|
@ -430,26 +401,27 @@ G29_TYPE GcodeSuite::G29() {
|
|||
|
||||
planner.synchronize();
|
||||
|
||||
if (!faux) remember_feedrate_scaling_off();
|
||||
|
||||
// Disable auto bed leveling during G29.
|
||||
// Be formal so G29 can be done successively without G28.
|
||||
if (!no_action) set_bed_leveling_enabled(false);
|
||||
|
||||
// Deploy certain probes before starting probing
|
||||
#if HAS_BED_PROBE
|
||||
// Deploy the probe. Probe will raise if needed.
|
||||
if (probe.deploy()) {
|
||||
if (ENABLED(BLTOUCH))
|
||||
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
||||
else if (probe.deploy()) {
|
||||
set_bed_leveling_enabled(abl_should_enable);
|
||||
G29_RETURN(false);
|
||||
}
|
||||
#endif
|
||||
|
||||
if (!faux) remember_feedrate_scaling_off();
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
if (!no_action)
|
||||
#endif
|
||||
if (gridSpacing != bilinear_grid_spacing || probe_position_lf != bilinear_start) {
|
||||
if (TERN_(PROBE_MANUALLY, !no_action)
|
||||
&& (gridSpacing != bilinear_grid_spacing || probe_position_lf != bilinear_start)
|
||||
) {
|
||||
// Reset grid to 0.0 or "not probed". (Also disables ABL)
|
||||
reset_bed_level();
|
||||
|
||||
|
@ -560,8 +532,7 @@ G29_TYPE GcodeSuite::G29() {
|
|||
PR_INNER_VAR = abl_probe_index - (PR_OUTER_VAR * PR_INNER_END);
|
||||
|
||||
// Probe in reverse order for every other row/column
|
||||
bool zig = (PR_OUTER_VAR & 1); // != ((PR_OUTER_END) & 1);
|
||||
|
||||
const bool zig = (PR_OUTER_VAR & 1); // != ((PR_OUTER_END) & 1);
|
||||
if (zig) PR_INNER_VAR = (PR_INNER_END - 1) - PR_INNER_VAR;
|
||||
|
||||
probePos = probe_position_lf + gridSpacing * meshCount.asFloat();
|
||||
|
@ -576,19 +547,14 @@ G29_TYPE GcodeSuite::G29() {
|
|||
// Is there a next point to move to?
|
||||
if (abl_probe_index < abl_points) {
|
||||
_manual_goto_xy(probePos); // Can be used here too!
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
soft_endstops_enabled = false;
|
||||
#endif
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
TERN_(HAS_SOFTWARE_ENDSTOPS, soft_endstops_enabled = false);
|
||||
G29_RETURN(false);
|
||||
}
|
||||
else {
|
||||
|
||||
// Leveling done! Fall through to G29 finishing code below
|
||||
|
||||
SERIAL_ECHOLNPGM("Grid probing done.");
|
||||
|
||||
// Re-enable software endstops, if needed
|
||||
TERN_(HAS_SOFTWARE_ENDSTOPS, soft_endstops_enabled = saved_soft_endstops_state);
|
||||
}
|
||||
|
@ -599,11 +565,9 @@ G29_TYPE GcodeSuite::G29() {
|
|||
if (abl_probe_index < abl_points) {
|
||||
probePos = points[abl_probe_index];
|
||||
_manual_goto_xy(probePos);
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
soft_endstops_enabled = false;
|
||||
#endif
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
TERN_(HAS_SOFTWARE_ENDSTOPS, soft_endstops_enabled = false);
|
||||
G29_RETURN(false);
|
||||
}
|
||||
else {
|
||||
|
@ -670,10 +634,8 @@ G29_TYPE GcodeSuite::G29() {
|
|||
|
||||
TERN_(AUTO_BED_LEVELING_LINEAR, indexIntoAB[meshCount.x][meshCount.y] = ++abl_probe_index); // 0...
|
||||
|
||||
#if IS_KINEMATIC
|
||||
// Avoid probing outside the round or hexagonal area
|
||||
if (!probe.can_reach(probePos)) continue;
|
||||
#endif
|
||||
// Avoid probing outside the round or hexagonal area
|
||||
if (TERN0(IS_KINEMATIC, !probe.can_reach(probePos))) continue;
|
||||
|
||||
if (verbose_level) SERIAL_ECHOLNPAIR("Probing mesh point ", int(pt_index), "/", int(GRID_MAX_POINTS), ".");
|
||||
TERN_(HAS_DISPLAY, ui.status_printf_P(0, PSTR(S_FMT " %i/%i"), GET_TEXT(MSG_PROBING_MESH), int(pt_index), int(GRID_MAX_POINTS)));
|
||||
|
@ -898,11 +860,7 @@ G29_TYPE GcodeSuite::G29() {
|
|||
|
||||
// Unapply the offset because it is going to be immediately applied
|
||||
// and cause compensation movement in Z
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
const float fade_scaling_factor = planner.fade_scaling_factor_for_z(current_position.z);
|
||||
#else
|
||||
constexpr float fade_scaling_factor = 1.0f;
|
||||
#endif
|
||||
const float fade_scaling_factor = TERN(ENABLE_LEVELING_FADE_HEIGHT, planner.fade_scaling_factor_for_z(current_position.z), 1);
|
||||
current_position.z -= fade_scaling_factor * bilinear_z_offset(current_position);
|
||||
|
||||
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR(" corrected Z:", current_position.z);
|
||||
|
|
Loading…